25
MA_VEB200-1-2_A2_181015_en
3.8
The blade of the thread trimmer is activated by a rotary magnet, to which an
electric release control system (microswitch) is connected. This prevents the
machine from starting when the blade is no longer in its inital position. Thus the
release control system prevents a possible collision between blade and looper.
Thread trimmer (Fig. 14)
3.8.1
Removing and remounting of the thread trimmer drive (Fig. 14)
A t t e n t i o n !
Switch off machine electrically!
1.
Remove plug (1).
2.
Loosen the screw (2) and remove from blade (3), spring (4) and disc (5).
3.
Loosen the screw (6) on the needle plate clamp (7) and remove the thread
trimmer drive.
4.
Installation in reverse order.
Ensure the blade is in correct position on the shaft!