29
MA_VEB200-1-2_A2_181015_en
3.11
Positions
Function
Parameter
Setting the reference position
F-170
This function sets the reference position.
Function
Parameter
Setting positions 1 and 2
F-171
This function sets the two positions.
The AB611A control has two positions. The positions are set exclusively by
programming the control.
A position is determined by a position input and output value. The values
correspond to the number of increments (steps), counted from an entered
reference position. A rotation is divided into 360 steps (increments), i.e. 1 step
= 1 degree.
N O T E !
To ensure a safe and proper process, must be between the two positions
must defer by at least 50 steps (increments).
Additionally there must be 25 steps between position input value and
output value for the same position (very important for internal control
functions).
For the precise programming of the individual positions refer to chapter “3.12
Setting the positions”.
The setting of the positions can be easily checked using the F-172 function.
Refer to chapter “3.13 Display of the needle positions”.