27
MA_VEB200-1-2_A2_181015_en
3.8.2
-
The thread trimmer drive must be inserted as far as it will go into the needle
plate clamp.
Swivel the drive backwards so that there is a gap of about 1 mm between
the drive and the sewing head.
Adjustment (Fig. 14)
-
The blade of the knife has until about 2 - 3 mm from needle lever, stand
forward, readjust if necessary.
Remove clamp (8).
Loosen the screws (9) and (10) on the small gearwheel (11) and adjust by
turning the blade shaft.
Push together gearwheel and blade shaft to the limit and tighten.
-
Setting the microswitch (12) and gearwheel (11).
-
When replacing the rotary magnet (13), ensure that the tooth gap between
the gearwheels is approx. 0.1 mm.
Ensure free movement of parts!
Fig. 15