Страница 1: ...1 Butterfl y Streamline Supplies Pty Ltd 9 Joseph Baldwin Place Shepparton Victoria 3630 Ph 03 5831 5555 Fax 03 5821 3633 Operating Instructions Automatic ...
Страница 2: ...ol knob made of plastic material Electro mechanically controlled brewing group made of solid brass 4 8 kg with electronic dosing control via programmable touch pad Autonomy 50 medium size espresso coffees Average brew time 30 seconds approx Optional facility for use of coffee pods Introduction Please read this technical handbook carefully since it provides important information on the correct inst...
Страница 3: ...emperature above freezing 0º C or 32º F This prevents any possible damage to pipes and boiler All maintenance procedures must be carried out exclusively by authorized technicians and all spare parts must be genuine Any modification or forcing performed by persons not authorized by the Manufacturer will void all warranties covering the appliance The motor pump set must be positioned away hydraulic ...
Страница 4: ...efill is standard Built in pump Automatic Espresso coffee machine with microprocessor controlled volumetric dosing control programming via digital keyboard Automatic boiler water refill is standard Built in pump Lever Espresso coffee machine with lever operated manual dosing control Automatic water boiler refill is standard Built in pump ...
Страница 5: ...for coffee delivery control filter holder spouts coffee brewing group Cup tray when flashing Hot water wand control knob filter holder drip tray with grid steam wand main switch pressure gauge for boiler steam wand control knob water tank underneath cup tray adjustable rubber feet Hot water wand ...
Страница 6: ...ea chocolates etc HOT WATER TAP This delivers hot water CONTROL MONITORING DEVICES Pressure gauge Indicates the boiler pressure and the working pressure of the pump Pressure switch This is used to keep the boiler water temperature constant by controlling the heating elements based on the boiler pressure Automatic Boiler Water Level Control Electronic circuitry used to keep the boiler water level c...
Страница 7: ...nufacturer or is components are other than those recommended by the Manufacturer used for installation or maintenance of the appliance the conformity declaration of the product will be voided and also the Manufacturer s warranty Possible replacement of the supply cable If damaged must be performed immediately and exclusively by service staff qualified or authorized by the Manufacturer in order to ...
Страница 8: ...to the water tank 3 Put cup tray back to its original position 4 Put main switch in ON position and verify the built in pilot light is on thus indicating machine electrical circuits are powered 5 Wait until the boiler pressure gauge indicates 1 2 bar approx after 15 min When above pressure is reached the machine is ready for use 6 Open steam valve for a few second and then close it again 7 Make su...
Страница 9: ...4 18 grams approx of ground coffee 2 Press coffee into the filter holder by pushing the tamper available in the dosing grinder 3 Remove possible ground coffee overflows from filter holder surface 4 Insert filter holder into delivery group by keeping handle towards left side to enable insertion then rotate holder handle towards right side until locked 5 Place two empty espresso cups below the filte...
Страница 10: ... should always be cold just out from fridge 3 The steam tip should be introduced by 1 2 cm approx 4 The steam arm should be tilting in such a way that the steamjets impress a rotary push to the milk while in taking some air from the top 5 Pressure valve knob should be opened proportionally to the frothing results WARNING Risk of burning Handle containers and jugs with care when steaming drinks WAR...
Страница 11: ...itches ON 4 Push the same key again when the correct quantity of coffee is reached the relevant LED switches OFF 5 Repeat steps 2 3 and 4 operation for dose setting of remaining does keys NOTE The programming operation between a key and the other has to be completed within 10 seconds otherwise the programming mode will automatically switch OFF In this case repeat step 1 and continue programming of...
Страница 12: ...y steamed drinks Do it without touching the wands directly Caution HOT Surface Manufacturer recommended weekly cleaning operations The group and shower plate are cleaned by putting one teaspoon of special espresso machine detergent in the blind filter and then inserting it into the group Press the button for semi automatic working and wait about 30 seconds Push this button again to stop Repeat thi...
Страница 13: ...al Data Mechanical features Supporting structure made of chemically treated and painted sheet steel to prevent corrosion The cabinet lower portion is provided with 4 adjustable rubber feet to optimize vibrations Front covering panels made of stainless steel Removable top panel made of stainless steel complete with metallic rails providing function of cup tray and cover to protect access to interna...
Страница 14: ...e contact operating range 1 1 to 1 4 bar Vibration type water pump with non return valve applied to the related hydraulic circuit and automatic over pressure discharge system Electronic control card for boiler tank level and automatic programmable dosing system via volumetric flow rate counter and 5 key electronic touch pad Boiler anti vacuum valve Boiler over pressure valve with calibrated trip a...
Страница 15: ... Replace heat exchanger 3 Replace solenoid valve water leakages on table top 1 Exhaust basin is dirty 2 Exhaust pipe is disconnected or clogged 1 Clean exhaust basin 2 Replace exhaust pipe Coffee dregs are wet 1 Coffee grinding is too fine 2 Group is still cold 3 Group solenoid valve doesn t work properly 1 Adjust grinding degree 2 Wait for appliance to get warm 3 Clean group exhaust system Coffee...
Страница 16: ...of in line water filter periodic change of water filter damage in transit damage due to incorrect installation or maintenance periodic regeneration of water filter not effected problems caused from the electric and hydraulic supplies of the client installation by non authorized persons non genuine parts seals filters gutters etc Not included in the warranty conditions are incorrect use of the mach...