installation instructions - electric products
connecting the electricity supply - terminal
Block
This appliance must be fitted using
a double pole unit of 45 ampere
minimum capacity with 3mm
minimum contact at all poles.
Access to the mains terminal is gained
by removing the terminal block cover
at the rear of the appliance.
Connection should be made with a
10.0mm² twin and earth cable.
First strip the wires then push the
cable through the cable clamp.
Connect the cable to the terminal
block and tighten the cable clamp
screws - see diagram.
Refit the terminal box cover.
Sufficient cable should be used to
allow the cooker to be pulled out, but
must hang clear of the floor so it does
not become twisted or trapped when
the cooker is pushed back.
Please ensure that the user has this copy
of the handbook, and the appliance is in
place. Thank you.
•
•
•
•
•
•
•
50
Installing Your Cooker
Connecting the electricity supply - Terminal Block
type B
�
This appliance must be fitted using a double pole unit
of 45 ampere minimum capacity with 3mm minimum
contact at all poles.
�
Access to the mains terminal is gained by removing the
terminal block cover at the rear of the appliance.
�
Connection should be made with a 10.0mm
2
twin and
earth cable.
�
First strip the wires then push the cable through the
cable clamp.
�
Connect the cable to the terminal block and tighten the
cable clamp screws - see diagram.
�
Refit the terminal box cover.
�
Sufficient cable should be used to allow the cooker to
be pulled out, but must hang clear of the floor so it
does not become twisted or trapped when the cooker
is pushed back.
Please ensure that the user has this copy of the
handbook, and the appliance is in place. Thank you.