FP10 Lafayette - Installation and Operation Manual
43
6.3.2
Minimum Heart Extension Requirements
The hearth extension floor area must extend at least 18" (457 mm)* in front of the hearth
(A)
and at least
8" (203 mm) on each side of the door opening (
D
). The joint between the hearth extension and the fireplace
hearth needs to be made of non-combustible material such as sheet metal (not included).
* On a raised base installation of more than 4", a non-combustible hearth extension floor area must extend
at least 16" (406 mm) in front of the hearth.
CLEARANCES
A
18" (457 mm)
B
41.5" (1054 mm)
C
8" (203 mm)