Room Calibration
Dirac Live®
6
Introduction
Setup
Measure
Optimize
Export
35
6.9) Once all measurements are completed, you will be able to visualise magnitude and impulse
responses of all speakers. In addition, Dirac Live
®
will add the default recommended target curve
as well as the window of correction deduced from the measurements. In this Quick Guide, we will
follow Dirac Live
®
recommendation to proceed. Shall you need to customize these two elements,
please refer to the
StormAudio_Dirac Live CT_Installer_Manual_rev 3.pdf
to find the descriptions
of all the adjustments options available.
1.
The purple Target Curve can be
adjusted by moving the markers
and markers can be added by double
clicking on the curve at the needed
frequency.
You can Save and Load your own
modified Target Curve.
2.
It is possible to limit the correction to a
certain frequency range in order to avoid
low frequency correction in speakers limited
or not capable in this area. The same applies
in high frequency. By default, correction
window is kept full frequency spectrum.
3.
Creation of the corrected curve is done real time
at each target curve modification. It can be
shown by ticking the corresponding box.
1
2
i
3
i