113
External cleaning of spray device
Wipe paint off the spray device's housing with a soft, water or solvent-dampened cloth.
Nozzles:
The nozzles must be exchanged at regular intervals depending on wear and tear; this depends on the properties of the
material used.
Never spray with a worn-out nozzle. See troubleshooting, page 21.
Storage
NOTE:
Use CorroCheck to hinder locking or rusting of internal pump components.
1. use the material hopper to mix 0.12 Liter CorroCheck
with 0.12 Liter water.
2. Screw on the hopper, place the ventilation/discharge
valve in the upwards position, and hold down the trigger
for approx. 10 seconds.
3. Turn the nozzle to the cleaning position, place the ven-
tilation/discharge valve in the downwards position and
direct the spray device into a garbage bin. Hold down the
trigger for 1 or 2 seconds.
4. Dispose of the used CorroCheck mixture in a material
hopper in the correct manner and rinse the hopper with
water.
5. Store the spray device in a building at a cool, dry place.
The device may only be stored in a vertical standing posi-
tion.