Chapter 1. Product Description
EK–SMCPP–UG. A01
1–27
Table 1–3 ECB Status Indications
LED Status
Battery Status
System power is on and the ECB is fully charged.
System power is on and the ECB is charging.
System power is off and the ECB is supplying power to the cache.
System power is off and the ECB is not supplying power to the cache.
LEGEND
=Off
= On
= Blink
fast
= Blink
slow
The ECB SBB is mounted at the top of the SW370 cabinet. A Y-cable connects
the ECB to the array controller cache module. The cache is mounted under the
controller and is identified by the single plug in the middle of the module (Figure
1-17). Cache module to ECB cables are factory installed.
CAUTION
The ECB cable is configured in a “Y” for
convenient routing within the cabinet. The cable is
only to be used to connect ONE battery to ONE
cache module. Do not connect both ends of the
ECB “Y” cable at the same time during normal
operation. See chapter 5 of this manual for ECB
replacement.