RA7000 and ESA10000 Storage Subsystems
4–20
EK–SMCPP–UG. A01
Figure 4–6 I/O Module LEDs
CXO5947A
External
TERM POWER
disable LED
Internal
TERM POWER
disable LED
•
The green internal and external TERMPOWER LEDs are ON during normal
operation.
•
Whenever there a TERMPOWER over-current condition, the associated LED
is OFF.
When there is an internal TERMPOWER over-current condition, you must
replace the I/O module. When there is an external TERMPOWER over-current
condition, you must first replace the associated cable. If this not correct the
problem, replace the I/O module.