Owner’s Manual #513532-5 Rev.1
22
E111I/F111I Model Machines
Error Code 5 - Freezing Cylinder Sensor
The Freezing Cylinder Sensor Error (E5) indicates
a failure of the barrel sensor or that the sensor
is out of range. If the control panel displays an
E5, place the Freezing Cylinder Off-On switch
Off and back On. If the error persists, contact
your Authorized Stoelting Distributor for further
assistance.
NOTE
When the machine encounters a Freezing Cylinder
Sensor Error, the machine will continue to run using
preset timers. This mode will allow the operator to
continue serving product until the machine can be
serviced.
Error Code 6 - Hopper Sensor (single hopper machines)
The Hopper Sensor Error (E6) indicates a failure
of the hopper sensor or that the sensor is out of
range. If the control panel displays an E6, turn
the left Main Power Off-On switch Off and back
On. If the error persists, contact your Authorized
Stoelting Distributor for further assistance.
Error Code 7 - Drive Motor
If the control panel displays a Drive Motor Error
(E7), the control does not sense current coming
from the drive motor. Turn the Freezing Cylinder
Off-On switch Off and back On. If the error persists,
contact your Authorized Stoelting Distributor for
further assistance.
Error Code 8 - Cab Sensor
A Cab Sensor Error (E8) will not occur on the
machine.
Error Code 9 - High Pressure Cutout
High Pressure Cutout Errors (E9) are usually
caused by a dirty or ineffi cient condenser. If the
control panel displays an E9 on an air cooled
machine, check for proper air clearance around
the machine. If the error persists, contact your
Authorized Stoelting Distributor for further
assistance.
Error Code 10 - Auxiliary Sensor
An Auxiliary Temperature Sensor Error (E10)
occurs if the temperature sensor on the control
board fails. Turn the Freezing Cylinder Off-On
switch Off and back On. If the error persists,
contact your Authorized Stoelting Distributor for
further assistance
Error Code 11 - Low Temperature
The Low Temperature Error (E11) occurs when
the temperature of the gas refrigerant at the barrel
sensor falls below -20°F. Although the machine
will not shut down, the active freezing cycle
will immediately end. This error usually occurs
when the machine continues to run in a low mix
condition or if the machine runs out of mix. The
product towards the front of the barrel tends to
freeze solid.
Error Code 12 - Left Hopper Sensor
The Left Hopper Sensor Error (E12) will not occur
on the machine.
Error Code 13 - Right Hopper Sensor
The Right Hopper Sensor Error (E13) will not
occur on the machine.
Alternating Flashing Control Panel Lights
The display panel lights will fl ash in an alternating
sequence under any error codes. Clear the error
and place the Freezing Cylinder Off-On switch in
the Off position and back in the On position.
Содержание E111I
Страница 1: ...E111 F111 IntelliTec Models OPERATORS MANUAL Manual No 513532 5 Rev 1...
Страница 2: ......
Страница 6: ......
Страница 10: ...Owner s Manual 513532 5 Rev 1 4 E111I F111I Model Machines...
Страница 20: ...Owner s Manual 513532 5 Rev 1 14 E111I F111I Model Machines...
Страница 22: ...Owner s Manual 513632 5 Rev 1 16 E111I F111I Model Machines Figure 4 2 IntelliTec Control Menu Settings...
Страница 30: ...Owner s Manual 513532 5 Rev 1 24 E111I F111I Model Machines...
Страница 34: ...Owner s Manual 513532 5 Rev 1 28 E111I F111I Model Machines...