Temperature Adjustment

To display target set point; in programming mode it selects a parameter or confirm an operation.

To start a manual defrost.

To see the maximum stored temperature; in programming mode it browses the parameter codes or
increases the displayed value.
To see the minimum stored temperature; in programming mode it browses the parameter codes or
increases the displayed value.

To switch the instrument OFF, if 

onF = oFF

.

Not enabled.

(DEF)

KEY FUNCTIONS:

(UP)

(DOWN)

To lock and unlock the keyboard.

To return to the room temperature display.

KEY COMBINATIONS:

1.   Push and immediately release the 

SET

 key, the display will show the set point value

2.   Push and immediately release the 

SET

 key or wait 5 seconds to display the probe value again

HOW TO SEE THE SET POINT:

1.   Push the 

SET

 key for more than 2 seconds to change the set point value

2.   The value of the set point will be displayed and the “°C” LED starts blinking

4.   To memorise the new set point value push the 

SET

 key again or wait 10 seconds

HOW TO CHANGE THE SET POINT:

3.   To change the set point value push the      or      arrows within 10 seconds

To enter in programming mode. (Contact the Stoddart Service Department)

Note:

•  The temperature can be set between 65°C and 95°C� How to set the temperature is shown below
•  Different modes require different temperatures
•  The temperature probe only measures the temperature of the water/air, NOT the food temperature

Operation

Power

•  Heat Lamps can be switched ON or OFF with the GANTRY button on the unit
•  Lamps MUST be switched ON when the unit is in operation� Steam from operating as a wet unit and/or steam from foods can pool on 

the lamps and damage the wiring

Surfaces

•  Nothing should be stored on the top of the gantry
•  When operating, the surfaces may be hot� Signage should be displayed for personal and customers to ensure no one will burn 

themselves

Rear Sliding Doors

•  As glass can be HOT, ensure the rear door slide are OPENED and CLOSED with the glass pulls

IMPORTANT

Where a gantry is fi tted over the bain marie, ensure that the 

lamps are always on when operating as a wet unit.

Содержание Culinaire CH.BMC.D.GSB

Страница 1: ...P IN Models CH BMC D GSB CH BMC D GSF CH BMC U GSB CH BMC U GSF CH IBGJ BMC U GSB CH IBGJ BMC U GSF CH IBGS BMC U GSB CH IBGS BMC U GSF CH IBSJ BMC U GSB CH IBSJ BMC U GSF CH IBSS BMC U GSB CH IBSS BM...

Страница 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 3: ...overs Dividers 10 Bain Marie Element Covers Bain Marie Dividers Specification Technical Specifications 11 CH BMC D CH BMC U CH IBXX BMC U GSF CH IBXX BMC U GSF Operation Initial Start up Operation 17...

Страница 4: ...his product is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or in...

Страница 5: ...bjects to activate controls If any fault is detected refer to troubleshooting The manufacturer declines any liability for damages to persons and or things due to an improper wrong and or unreasonable...

Страница 6: ...de Explanation CH Culinaire Heated IBSS Island Buffet Stainless Steel Top and Stainless Steel Panels IBSJ Island Buffet Stainless Steel Top and Joinery Panels IBGS Island Buffet Stone Top and Stainles...

Страница 7: ...all protective plastic film tapes ties and packers before installing and operating Clean off any remaining residue from the interior exterior of the unit using a clean cloth dampened with warm soapy w...

Страница 8: ...hecked high mineral water can corrode the elements and taint the water food If needed a filtration system should be installed The unit is supplied with a G BSP Water Connection for filling the well Th...

Страница 9: ...ody If the power point is not readily accessible turn the equipment o at the isolation switch or the circuit breaker in the switchboard Attach a yellow CAUTION DO NOT OPERATE tag This must be performe...

Страница 10: ...en on the actual unit being fitted WELL OPENING SIZES TO BAIN MARIE Module Width Depth 3 1057 548mm 4 1397 548mm 5 1737 548mm 6 2077 548mm 7 2417 548mm 8 2757 548mm Stainless Steel Benchtop Stone Benc...

Страница 11: ...om au www stoddart co nz Install as shown when 1 1 module dividers are provided dividers are sold separately Element covers are placed over the top of the elements for protection Without Element Cover...

Страница 12: ...Hz 220 240V 50Hz Power kW 2 85kW 3 9kW 4 95kW Current average Connection 1 Phase Neutral Earth 3 Phase Neutral Earth Temperature Range 65 90 C Water Connection 15mm Diameter Waste Connection 50mm Diam...

Страница 13: ...Page 12 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz Specification...

Страница 14: ...50Hz Power kW 2 85kW 3 9kW 4 95kW Current average Connection 1 Phase Neutral Earth 3 Phase Neutral Earth Temperature Range 65 90 C Water Connection 15mm Diameter Waste Connection 50mm Diameter SPECIFI...

Страница 15: ...Page 14 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz Specification...

Страница 16: ...9kW 4 95kW Current average Connection 1 Phase Neutral Earth 3 Phase Neutral Earth Temperature Range 65 90 C Water Connection 15mm Diameter Waste Connection 50mm Diameter SPECIFICATIONS Model CH IBXX B...

Страница 17: ...research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz 1000 1260 900 360 1380 1720 2060 2400 2740 3080 Plan View Front Ele...

Страница 18: ...vent contaminants entering the pans When operating the surfaces may be hot Signage should be displayed for personal and customers to ensure no one will burn themselves This unit MUST be completely emp...

Страница 19: ...e with a temperature probe to ensure it is above the regulated 65 C serving temperature Food Temperature All storage of food should comply with local health standards and regulations All pans should b...

Страница 20: ...m temperature display KEY COMBINATIONS 1 Push and immediately release the SET key the display will show the set point value 2 Push and immediately release the SET key or wait 5 seconds to display the...

Страница 21: ...with the glass pulls IMPORTANT Where a gantry is fitted over the bain marie ensure that the lamps are always on when operating as a wet unit Bulbs should be allowed to cool for 10 15 minutes before r...

Страница 22: ...rasive pads or cleaners for cleaning All metal surfaces should be checked while cleaning for damage scuffs or scrapes as these can lead to rust and further damage to the product Mild rust and or corro...

Страница 23: ...polish 4 Wipe clean using a cloth dampened with clean warm water until all Stainless Cleaner and soil has been removed 5 Using a clean sanitised cloth thoroughly wipe the stainless steel and metal par...

Страница 24: ...does not reach temperature Temperature not set to the right setting O Check setting and adjust the temperature Exhaust fan above the unit O Move unit exhaust fan Cold items in units O Remove items and...

Страница 25: ...ollect the remaining cabinet shelves etc There may be special requirements or conditions Information on the disposal of refrigeration appliances can be obtained from Your supplier Government authoriti...

Страница 26: ...Page 25 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 27: ...Page 26 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 28: ...7694 New Zealand Sales Spare Parts Tel 0800 79 1954 Email sales stoddart co nz Email spares stoddart co nz Service Spare Parts Tel 0800 935 714 Email service stoddart co nz Email spares stoddart co nz...

Отзывы: