4
4.2
Encoder
4.2.1
X120
Prerequisite for using interface X120:
•
REA 5001 or
•
XEA 5001
Information
Remember that the encoder interfaces can usually evaluate or
simulate several systems (e.g., EnDat® and incremental encoder).
In the parameters enter the particular system that you are
connecting to an interface. Please consult the inverter operating
manual in this case.
Information
Interface X120 is a double interface on option board XEA 5001. The
double interface makes it possible to distribute encoder signals to
other inverters without a great amount of wiring work. This is why
the two sub D connections have the same allocation.
General specifications
U
A
18 V (See encoder power below.)
I
A max
250 mA, Sum of X4, X120 and X140: 500 mA
Maximum cable length
50 m
Max. number of stations
1 master and 31 stations
Terminating resistance
120
Ω
Specifications of SSI (evaluation and simulation)
Switching frequency (SSI
master)
592 kHz (motor encoder) or 250 kHz (position encoder)
Code
Binary or gray
Encoder type
Multi-turn: 24 or 25-bits
Single-turn: 13 its (short) or 13 bits (tree)
Transmission
Double transmission can be switched off
Specifications of incremental and stepper motor signals (evaluation and simulation)
Limit frequency
Evaluation:
≤
1 MHz