Connection
Commissioning Instructions I/O Terminal Module
25
ID 441758.05
WE KEEP THINGS MOVING
4
Terminal description X140 resolver (REA 5001)
Pin
a)
Designation
Function
socket
1
Sin
Sine input
2
GND
Reference to pin 6
3
Cos
Cosine input
4
—
—
5
—
—
6
ErregungResolv
Resolver excitation signal
7
TempMotor
Connection MTF is output at X141, pin 1 if carried by the encoder
cable.
8
—
—
9
/Sin
Sine input (inverse)
10
—
—
11
/Cos
Cosine input (inverse)
12
—
—
13
—
—
14
TempMotor
Connection MTF is output at X141, pin 2 if carried by the encoder
cable.
15
—
—
a) View of sub D
9
15
1
8
Information
Note that the EnDat ®interface at X140 is used if a SDS 4000 is
replaced where a motor with an absolute encoder at X41 was
operated.
In this case, you can continue to use the previously used encoder
cable. The connection of the motor temperature sensor is carried in
this cable. For this reason, observe the chapter 4.3 X141: Motor
temperature sensor.