System layout 7
The controller calculates the temperature differences between
the collector sensors S1 and S3 and the tank sensor S2. If the
differences are larger than or identical to the adjusted switch-
on temperature difference (DT O), the respective solar pump
will be operated by relay 1 and / or relay 2, and the tank will
R1
R2
S1
S2
Arr 7
Display Channels
Channel
Description
Terminal
Page
COL1
x
Temperature collector 1
S1
37
TST
x
Temperature tank
S2
37
COL2
x
Temperature collector 2
S3
37
S4
x
Temperature sensor 4
S4
37
n1 %
x
Pump speed R1
R1
38
n2 %
x
Pump speed R2
R2
38
h P1
x
Operating hours R1
R1
38
h P2
x
Operating hours R2
R2
38
TIME
x
Time
-
34
be loaded until the switch-off temperature difference (DT F) or
the maximum tank temperature (S MX) is reached.
Sensor S4 can optionally be connected for measurement
purposes.