INSTALLATION  

COMMISSIONING

11. Commissioning

 

DANGER: Electrocution
Commissioning must only be carried out by an authorised 
contractor in accordance with safety regulations.

!

 

Damage to the appliance and the environment:

Open hot water faucet for a few minutes until water fl ow 
is continuous and all air is purged from water pipes. The 
appliance’s plastic cover must be installed before the circuit 
breaker is turned on.

 

Turn on circuit breaker to bring electrical power to the 
appliance.

 

Turn the temperature selector clockwise and anti-clockwise, to 
calibrate the temperature selector.

 

Adjust the water temperature to the desired level using the 
knob on the front cover of the appliance.

 

Turn on hot water and wait twenty seconds until temperature 
has stabilized. 

 

Check the water temperature with your hand and make sure 
that it does not feel too hot. Reduce temperature if this is 
necessary.

 

Explain to the user how the appliance works and familiarise 
him or her with its use.

 

Advise the user about possible hazards (hot water temperature 
up to 140 °F (60 °C). Hand over these instructions, to be kept 
for future reference.

 

A setting of 110°F (43°C) is recommended when the MegaBoost 
is installed on the outlet of the tank. When installed on the tank 
inlet, a setting of 120°F (49°C) is recommended.

11.1 Appliance 

handover

Explain the functions of the appliance to the user. Draw special at-
tention to the safety information. Hand the operating and installation 
instructions to the user.

12. Troubleshooting

 

DANGER: Electrocution

To test the appliance, it must be supplied with power.

12.1  Display options LED diagnostic „traffi c lights“

Display options

red

illuminates in case of faults

yellow

illuminates when the appliance is heating water

green

flashing: The appliance is supplied with power

1

26

_0

2

_02

_1

0

8

8

1  LED diagnostic “traffi c lights“

12.2 Fault 

table

Symptom

Possible Cause

Solution

No hot water

circuit breaker off

safety thermal cut-out 

tripped

turn circuit breaker on

reset thermal cut-out

not enough flow rate to 

activate appliance

clean filter screen at appliance

 

clean faucet aerator or shower 

head

Not enough hot water filter screen clogged

clean filter screen at appliance

Water not hot enough

water flow too high

reduce water flow rate until 

light on front cover stops blin-

king

 

 

supply correct voltage to ap-

pliance

 

If you are not able to resolve a problem please contact us, see 
last side, before removing the appliance from the wall. STIEBEL 
ELTRON is happy to provide technical assistance. In most in-
stances, we can resolve the problem over the phone.

13. Normal maintenance

STIEBEL ELTRON tankless water heaters are designed for a very long 
service life. Actual life expectancy will vary with water quality and 
use. The appliance itself does not require any regular maintenance.

However, to ensure consistent water fl ow, it is recommended to 
periodically remove scale and dirt that may build up at the aerator of 
the faucet(s), the fi lter screen in the appliance, or in the shower head.

Содержание MEGABOOST

Страница 1: ...105 F 120 F Residential Use 120 F 140 F Commercial Only F C Tankless electric booster for tank water heaters Off The MegaBoost is tested and certified by WQA against NSF ANSI 372 for lead free compliance STIEBEL ELTRON Inc 17 West Street West Hatfield MA 01088 Tel 413 247 3380 Fax 413 247 3369 Email info stiebel eltron usa com www stiebel eltron usa com ...

Страница 2: ...7 10 2 Terminal block_______________________________________________________ 7 11 Commissioning _________________________________________________ 8 11 1 Appliance handover________________________________________________ 8 12 Troubleshooting ________________________________________________ 8 12 1 Display options LED diagnostic traffic lights ________________ 8 12 2 Fault table_______________________...

Страница 3: ...ice technicians DANGER Electrocution Before proceeding with any installation adjustment al teration or service of this appliance all circuit breakers and disconnect switches servicing the appliance must be turned off Failure to do so could result in serious personal injury or death DANGER Electrocution Never remove the appliance cover unless the electricity servicing the appliance is turned off Fa...

Страница 4: ...he appliance will deliver any water temperature between 86 F 30 C and 140 F 60 C Please set the desired temperature using the knob on the front cover Note For reasons of appliance efficiency and durability scaling the optimum temperature setting lies between 86 F 30 C and 120 F 50 C In case the Power light is flashing while the appliance operates the water flow rate exceeds the heating capacity of th...

Страница 5: ...eater CAUTION Electrocution Unit must be installed in a vertical position with the water fittings pointing downward In this position the unit is splashproof so that no water can soak in 8 2 Choosing installation configuration The Megaboost can either pre heat an electric tank water heater or be pre heated by one The chart shows the effect of installation on the tank cold water inlet versus on the ta...

Страница 6: ...ated for maintenance purposes The tank water heater should have its own isolation valve in addition to the valve for the MegaBoost Cold water connection inlet is on the right side of the ap pliance hot water connection outlet is on the left side of appliance Tankless water heaters such as the MegaBoost are not required to be equipped with a Pressure and Temperature Relief Valve P T If the local in...

Страница 7: ...ections Then feed wires through strain relief clamp and tighten clamp down on wire The live wires must be connected to the slots on the terminal block marked L and L The ground wire must be connected to slot marked with the ground symbol Strain relief clamp with screws and rubber seal are provided 10 1 Temperature setting anti scalding protection 26_02_02_1089 Connect the lead of the electronic te...

Страница 8: ... at tention to the safety information Hand the operating and installation instructions to the user 12 Troubleshooting DANGER Electrocution To test the appliance it must be supplied with power 12 1 Display options LED diagnostic traffic lights Display options red illuminates in case of faults yellow illuminates when the appliance is heating water green flashing The appliance is supplied with power 1...

Страница 9: ... circuit breaker1 DP A 35 40 Min recommended wire size2 copper AWG 8 8 Min water flow to activate appliance GPM l min 0 26 1 Protection level according to IP 24 Max inlet water temperature F C 131 55 Nominal water volume GAL l 0 13 0 5 Working pressure max PSI bar MPa 150 10 1 Tested to pressure PSI bar MPa 300 20 2 Weight lbs kg 5 9 2 7 Water connections 1 2 NPT 1 This is our recommendation for o...

Страница 10: ...ermal cut out 286369 3 Electronic control appliance 291851 4 Coding plug 283455 5 Back panel 292578 6 Flow sensor DFE 286461 7 Cold water connection 291699 8 Filter screen 252430 9 Hot water connection 278634 10 Plastic cover 11 Wiring block 279998 12 Axis connection plug 254312 13 Electronic temperature control 286359 14 Temperature adjustment knob 254307 15 Outlet temperature sensor 280677 ...

Страница 11: ...as directed by Manufacturer and other than in accordance with applicable building codes 4 failure to maintain the Heater or to operate the Heater in accordance with the Manufacturer s specifications 5 operation of the Heater under fluctuating water pressure or in the event the Heater is supplied with non potable water for any duration 6 improper installation and or improper materials used by any ins...

Страница 12: ...s and technical changes Stand 8643 STIEBEL ELTRON Inc 17 West Street 01088 West Hatfield MA Tel 0413 247 3380 Fax 0413 247 3369 info stiebel eltron usa com www stiebel eltron usa com A 330773 40358 9271 4 AMHCMD CbJADD ...

Отзывы: