WARRANTY | ENVIRONMENT AND RECYCLING  

This Warranty is valid for U.S.A. & Canada only. Warranties may 
vary by country. Please consult your local Stiebel Eltron Repre-
sentative for the Warranty for your country.

Subject to the terms and conditions set forth in this limited 
warranty, Stiebel Eltron, Inc. (the “Manufacturer”) hereby 
warrants to the original purchaser (the “Owner”) that each 
Tankless Electric Domestic Hot Water Heater (the “Heater”) 
shall not (i) leak due to defects in the Manufacturer’s 
materials or workmanship for a period of seven (7) years 
from the date of purchase or (ii) fail due to defects in the 
Manufacturer’s materials or workmanship for a period of 
three (3) years from the date of purchase. As Owner’s sole 
and exclusive remedy for breach of the above warranty, 
Manufacturer shall, at the Manufacturer’s discretion, 
send replacement parts for local repair; retrieve the unit 
for factory repair, or replace the defective Heater with a 
replacement unit with comparable operating features. 
Manufacturer’s maximum liability under all circumstances 
shall be limited to the Owner’s purchase price for the 
Heater.

This limited warranty shall be the exclusive warranty 
made by the Manufacturer and is made in lieu of all other 
warranties, express or implied, whether written or oral, 
including, but not limited to warranties of merchantability 
and fi tness for a particular purpose. Manufacturer shall 
not be liable for incidental, consequential or contingent 
damages or expenses arising directly or indirectly from any 
defect in the Heater or the use of the Heater. Manufacturer 
shall not be liable for any water damage or other damage 
to property of Owner arising, directly or indirectly, 
from any defect in the Heater or the use of the Heater. 
Manufacturer alone is authorized to make all warranties 
on Manufacturer’s behalf and no statement, warranty or 
guarantee made by any other party shall be binding on 
Manufacturer.

Manufacturer shall not be liable for any damage 
whatsoever relating to or caused by:

1.  any misuse or neglect of the Heater, any accident to 

the Heater, any alteration of the Heater, or any other 
unintended use;

2.  acts of God and circumstances over 

which  Manufacturer  has  no  control;                                                                                                                                         
    

3.  installation of the Heater other than as directed by 

Manufacturer and other than in accordance with 
applicable building codes;

4.  failure to maintain the Heater or to operate the Heater 

in accordance with the Manufacturer’s specifi cations;

5.  operation of the Heater under fl uctuating water 

pressure or in the event the Heater is supplied with 
non-potable water, for any duration;

6.  improper installation and/or improper materials used 

by any installer and not relating to defects in parts or 
workmanship of Manufacturer;

7.  moving the Heater from its original place of installation;
8.  exposure to freezing conditions;
9.  water quality issues such as corrosive water, hard water, 

and water contaminated with pollutants or additives;

Should owner wish to return the Heater to manufacturer 
for repair or replacement under this warranty, Owner 
must fi rst secure written authorization from Manufacturer. 
Owner shall demonstrate proof of purchase, including a 
purchase date, and shall be responsible for all removal 
and transportation costs. If Owner cannot demonstrate a 
purchase date this warranty shall be limited to the period 
beginning from the date of manufacture stamped on the 
Heater. Manufacturer reserves the right to deny warranty 
coverage upon Manufacturer’s examination of Heater. 
This warranty is restricted to the Owner and cannot be 
assigned.

Some States and Provinces do not allow the exclusion 
or limitation of certain warranties. In such cases, the 
limitations set forth herein may not apply to the Owner. In 
such cases this warranty shall be limited to the shortest 
period and lowest damage amounts allowed by law. This 
warranty gives you specifi c legal rights and you may also 
have other rights which vary from State to State or Province 
to Province.

Owner shall be responsible for all labor and other charges 
incurred in the removal or repair of the Heater in the fi eld. 
Please also note that the Heater must be installed in such a 
manner that if any leak does occur, the fl ow of water from 
any leak will not damage the area in which it is installed.

!

 

The installation, electrical connection and first operati-
on of this appliance should be carried out by a qualified 
installer.

!

 

The company does not accept liability for failure of any 
goods supplied which have not been installed and ope-
rated in accordance with the manufacturer‘s 
instructions.

Environment and recycling

Please help us to protect the environment by disposing of the 
packaging in accordance with the national regulations for waste 
processing.

15. Warranty

Содержание MEGABOOST

Страница 1: ...105 F 120 F Residential Use 120 F 140 F Commercial Only F C Tankless electric booster for tank water heaters Off The MegaBoost is tested and certified by WQA against NSF ANSI 372 for lead free compliance STIEBEL ELTRON Inc 17 West Street West Hatfield MA 01088 Tel 413 247 3380 Fax 413 247 3369 Email info stiebel eltron usa com www stiebel eltron usa com ...

Страница 2: ...7 10 2 Terminal block_______________________________________________________ 7 11 Commissioning _________________________________________________ 8 11 1 Appliance handover________________________________________________ 8 12 Troubleshooting ________________________________________________ 8 12 1 Display options LED diagnostic traffic lights ________________ 8 12 2 Fault table_______________________...

Страница 3: ...ice technicians DANGER Electrocution Before proceeding with any installation adjustment al teration or service of this appliance all circuit breakers and disconnect switches servicing the appliance must be turned off Failure to do so could result in serious personal injury or death DANGER Electrocution Never remove the appliance cover unless the electricity servicing the appliance is turned off Fa...

Страница 4: ...he appliance will deliver any water temperature between 86 F 30 C and 140 F 60 C Please set the desired temperature using the knob on the front cover Note For reasons of appliance efficiency and durability scaling the optimum temperature setting lies between 86 F 30 C and 120 F 50 C In case the Power light is flashing while the appliance operates the water flow rate exceeds the heating capacity of th...

Страница 5: ...eater CAUTION Electrocution Unit must be installed in a vertical position with the water fittings pointing downward In this position the unit is splashproof so that no water can soak in 8 2 Choosing installation configuration The Megaboost can either pre heat an electric tank water heater or be pre heated by one The chart shows the effect of installation on the tank cold water inlet versus on the ta...

Страница 6: ...ated for maintenance purposes The tank water heater should have its own isolation valve in addition to the valve for the MegaBoost Cold water connection inlet is on the right side of the ap pliance hot water connection outlet is on the left side of appliance Tankless water heaters such as the MegaBoost are not required to be equipped with a Pressure and Temperature Relief Valve P T If the local in...

Страница 7: ...ections Then feed wires through strain relief clamp and tighten clamp down on wire The live wires must be connected to the slots on the terminal block marked L and L The ground wire must be connected to slot marked with the ground symbol Strain relief clamp with screws and rubber seal are provided 10 1 Temperature setting anti scalding protection 26_02_02_1089 Connect the lead of the electronic te...

Страница 8: ... at tention to the safety information Hand the operating and installation instructions to the user 12 Troubleshooting DANGER Electrocution To test the appliance it must be supplied with power 12 1 Display options LED diagnostic traffic lights Display options red illuminates in case of faults yellow illuminates when the appliance is heating water green flashing The appliance is supplied with power 1...

Страница 9: ... circuit breaker1 DP A 35 40 Min recommended wire size2 copper AWG 8 8 Min water flow to activate appliance GPM l min 0 26 1 Protection level according to IP 24 Max inlet water temperature F C 131 55 Nominal water volume GAL l 0 13 0 5 Working pressure max PSI bar MPa 150 10 1 Tested to pressure PSI bar MPa 300 20 2 Weight lbs kg 5 9 2 7 Water connections 1 2 NPT 1 This is our recommendation for o...

Страница 10: ...ermal cut out 286369 3 Electronic control appliance 291851 4 Coding plug 283455 5 Back panel 292578 6 Flow sensor DFE 286461 7 Cold water connection 291699 8 Filter screen 252430 9 Hot water connection 278634 10 Plastic cover 11 Wiring block 279998 12 Axis connection plug 254312 13 Electronic temperature control 286359 14 Temperature adjustment knob 254307 15 Outlet temperature sensor 280677 ...

Страница 11: ...as directed by Manufacturer and other than in accordance with applicable building codes 4 failure to maintain the Heater or to operate the Heater in accordance with the Manufacturer s specifications 5 operation of the Heater under fluctuating water pressure or in the event the Heater is supplied with non potable water for any duration 6 improper installation and or improper materials used by any ins...

Страница 12: ...s and technical changes Stand 8643 STIEBEL ELTRON Inc 17 West Street 01088 West Hatfield MA Tel 0413 247 3380 Fax 0413 247 3369 info stiebel eltron usa com www stiebel eltron usa com A 330773 40358 9271 4 AMHCMD CbJADD ...