OPERATION  

GENERAL

4

 | DHC-E 

WWW.STIEBEL-ELTRON-USA.COM

4. General

The tankless water heater differs from conventional storage type 
water heaters in several ways. It does not store hot water. Instead, 
water is heated instantaneously as it fl ows through the appliance. 
Due to the absence of stand-by losses, the appliance offers greater 
energy effi ciency than storage type water heaters.

The MegaBoost should be installed in conjunction with a storage 
tank water heater. 

MegaBoost can be installed on the cold water inlet or on the hot 
water outlet of the tank water heater. Installation at either location 
will greatly increase the amount of hot water the tank is able to de-
liver (fi rst hour rating). Either installation location will also shorten 
the recovery time necessary for the tank to recharge, but this effect 
is far greater with installation on the cold water inlet. 

°

F

°

C

26

_0

2

_02

_1

0

8

6

The input of heat into the water is electronically controlled. The 
appliance will deliver any water temperature between 86°F (30°C) 
and 140°F (60°C). Please set the desired temperature using the knob 
on the front cover.

 

Note:

For reasons of appliance effi ciency and durability (scaling), 
the optimum temperature setting lies between 86°F (30°C) 
and 120°F (50°C).

In case the “Power” light is fl ashing while the appliance operates, 
the water fl ow rate exceeds the heating capacity of the appliance. 
Reduce the hot water fl ow rate in order to let the appliance achieve 
the set point temperature. The maximum temperature is electroni-
cally limited to 140°F (60°C). In case you have questions regarding 
the way you plan to use the appliance, please call our technical 
service line, see last side.

5. Troubleshooting

Symptom

Possible Cause

Solution

No hot water

not enough flow rate 

to activate appliance

clean faucet aerator or shower head

Water not hot 

enough

water flow too high

reduce water flow rate until light on 

front cover stops blinking

If you cannot remedy the fault, notify the contractor who installed 
the appliance. To facilitate and speed up your enquiry, please pro-
vide the serial number from the type plate (000000-0000-000000).

Содержание MEGABOOST

Страница 1: ...105 F 120 F Residential Use 120 F 140 F Commercial Only F C Tankless electric booster for tank water heaters Off The MegaBoost is tested and certified by WQA against NSF ANSI 372 for lead free compliance STIEBEL ELTRON Inc 17 West Street West Hatfield MA 01088 Tel 413 247 3380 Fax 413 247 3369 Email info stiebel eltron usa com www stiebel eltron usa com ...

Страница 2: ...7 10 2 Terminal block_______________________________________________________ 7 11 Commissioning _________________________________________________ 8 11 1 Appliance handover________________________________________________ 8 12 Troubleshooting ________________________________________________ 8 12 1 Display options LED diagnostic traffic lights ________________ 8 12 2 Fault table_______________________...

Страница 3: ...ice technicians DANGER Electrocution Before proceeding with any installation adjustment al teration or service of this appliance all circuit breakers and disconnect switches servicing the appliance must be turned off Failure to do so could result in serious personal injury or death DANGER Electrocution Never remove the appliance cover unless the electricity servicing the appliance is turned off Fa...

Страница 4: ...he appliance will deliver any water temperature between 86 F 30 C and 140 F 60 C Please set the desired temperature using the knob on the front cover Note For reasons of appliance efficiency and durability scaling the optimum temperature setting lies between 86 F 30 C and 120 F 50 C In case the Power light is flashing while the appliance operates the water flow rate exceeds the heating capacity of th...

Страница 5: ...eater CAUTION Electrocution Unit must be installed in a vertical position with the water fittings pointing downward In this position the unit is splashproof so that no water can soak in 8 2 Choosing installation configuration The Megaboost can either pre heat an electric tank water heater or be pre heated by one The chart shows the effect of installation on the tank cold water inlet versus on the ta...

Страница 6: ...ated for maintenance purposes The tank water heater should have its own isolation valve in addition to the valve for the MegaBoost Cold water connection inlet is on the right side of the ap pliance hot water connection outlet is on the left side of appliance Tankless water heaters such as the MegaBoost are not required to be equipped with a Pressure and Temperature Relief Valve P T If the local in...

Страница 7: ...ections Then feed wires through strain relief clamp and tighten clamp down on wire The live wires must be connected to the slots on the terminal block marked L and L The ground wire must be connected to slot marked with the ground symbol Strain relief clamp with screws and rubber seal are provided 10 1 Temperature setting anti scalding protection 26_02_02_1089 Connect the lead of the electronic te...

Страница 8: ... at tention to the safety information Hand the operating and installation instructions to the user 12 Troubleshooting DANGER Electrocution To test the appliance it must be supplied with power 12 1 Display options LED diagnostic traffic lights Display options red illuminates in case of faults yellow illuminates when the appliance is heating water green flashing The appliance is supplied with power 1...

Страница 9: ... circuit breaker1 DP A 35 40 Min recommended wire size2 copper AWG 8 8 Min water flow to activate appliance GPM l min 0 26 1 Protection level according to IP 24 Max inlet water temperature F C 131 55 Nominal water volume GAL l 0 13 0 5 Working pressure max PSI bar MPa 150 10 1 Tested to pressure PSI bar MPa 300 20 2 Weight lbs kg 5 9 2 7 Water connections 1 2 NPT 1 This is our recommendation for o...

Страница 10: ...ermal cut out 286369 3 Electronic control appliance 291851 4 Coding plug 283455 5 Back panel 292578 6 Flow sensor DFE 286461 7 Cold water connection 291699 8 Filter screen 252430 9 Hot water connection 278634 10 Plastic cover 11 Wiring block 279998 12 Axis connection plug 254312 13 Electronic temperature control 286359 14 Temperature adjustment knob 254307 15 Outlet temperature sensor 280677 ...

Страница 11: ...as directed by Manufacturer and other than in accordance with applicable building codes 4 failure to maintain the Heater or to operate the Heater in accordance with the Manufacturer s specifications 5 operation of the Heater under fluctuating water pressure or in the event the Heater is supplied with non potable water for any duration 6 improper installation and or improper materials used by any ins...

Страница 12: ...s and technical changes Stand 8643 STIEBEL ELTRON Inc 17 West Street 01088 West Hatfield MA Tel 0413 247 3380 Fax 0413 247 3369 info stiebel eltron usa com www stiebel eltron usa com A 330773 40358 9271 4 AMHCMD CbJADD ...

Отзывы: