INSTALLATION
Specification
104
|DHE Connect | DHE Touch
www.stiebel-eltron.com
17.3 Hot water output
The DHW output is subject to the mains voltage, the appliance's
connected load and the cold water inlet temperature. The rated
voltage and rated output can be found on the type plate.
Connected load in kW
38 °C DHW output in l/min.
Rated voltage
Cold water inlet temperature
380 V
400 V
415 V
5 °C
10 °C
15 °C
20 °C
16.2
7.0
8.3
10.1
12.9
19
8.2
9.7
11.8
15.1
21.7
9.4
11.1
13.5
17.2
18
7.8
9.2
11.2
14.3
21
9.1
10.7
13.0
16.7
24
10.4
12.2
14.9
19.0
19.4
8.4
9.9
12.0
15.4
22.6
9.8
11.5
14.0
17.9
25.8
11.2
13.2
16.0
20.5
24.4
10.6
12.4
15.2
19.4
27
11.7
13.8
16.8
21.4
29.1
12.6
14.8
18.1
23.1
Connected load in kW
50 °C DHW output in l/min.
Rated voltage
Cold water inlet temperature
380 V
400 V
415 V
5 °C
10 °C
15 °C
20 °C
16.2
5.1
5.8
6.6
7.7
19
6.0
6.8
7.8
9.0
21.7
6.9
7.8
8.9
10.3
18
5.7
6.4
7.3
8.6
21
6.7
7.5
8.6
10.0
24
7.6
8.6
9.8
11.4
19.4
6.2
6.9
7.9
9.2
22.6
7.2
8.1
9.2
10.8
25.8
8.2
9.2
10.5
12.3
24.4
7.7
8.7
10.0
11.6
27
8.6
9.6
11.0
12.9
29.1
9.2
10.4
11.9
13.9
17.4 Application areas / Conversion table
Specific electrical resistance and specific electrical conductivity.
Standard specifica-
tion at 15 °C
20 °C
25 °C
Resist-
ance
ρ ≥
Conductivity
σ
≤
Resist-
ance
ρ ≥
Conductivity
σ
≤
Resist-
ance
ρ ≥
Conductivity
σ
≤
Ωcm
mS/m μS/cm
Ωcm
mS/m μS/cm
Ωcm
mS/m
μS/cm
900
111
1111
800
125
1250
735
136
1361