Z001019/0_7_January 2011
Page GENERAL-27
GENERAL
SERVICE MANUAL MARINE ENGINES
ToC
Operating Parameter
Inverse position shut
down (SOLAS)
During break in phase
Additional
Tool-Readings
Steyr Diag
Break-in
phase
Panel
Indication
After engine stop
horn remains
switched ON until
ignition reset
Indication light
"CEL" is switched
ON
Effect
noticed
Engine shut
down beyond
70° deg. angle
Cel-ON at high
accelerator
position (more
than 75%)
Action or
possible reason
Reset through ignition
OFF and then ON
See information break
in procedure
D 2
Diagnostic system
The electronic management system monitors the following engine parameters:
oil pressure, boost pressure, coolant temperature, exhaust pipe temperature (Hi-riser), sensor control rack,
potentiometer accelerator, speed signal
The electronic management system carries out self-diagnostic and/or plausibility checks for all input values and
sensor connections. In case of irregularities, there is an optical or audible warning signal. (see page 71)
Existing active failures remain stored until the problem has been solved and the code has been cleared from the
memory.
To select stored error codes, a PC with diagnostic program (VR00134/0) or diagnostic tool (VR00135/1) is
necessary.
Malfunction during operation is ranked in three different categories intermittent failure, non essential failure and
essential failure.
Optical and accustical warning signals are explained on the following tables.
"Operating Status and Error Report"
Содержание M0114K33
Страница 2: ...THIS PAGE IS INTENTIONALLY BLANK ...
Страница 140: ...01 ENGINE PageENGINE 80 Z001019 0_6_July 2008 SERVICE MANUAL MARINE ENGINES THIS PAGE IS INTENTIONALLY BLANK ToC ...
Страница 148: ...01 ENGINE PageENGINE 88 Z001019 0_6_July 2008 SERVICE MANUAL MARINE ENGINES THIS PAGE IS INTENTIONALLY BLANK ToC ...