Operation Manual (Version: B)
31
Type SP
1. Switch the BDC switch at the right hand side of the control box to '0' to activate
BDC.
2. Press [Deck up], after the deck has reached its highest position and the lip has
extended slightly (approx 5 deg), the pump shuts off automatically.
3. Release [deck up]. The deck descends to its lowest position. The lip stays pendant
below docking level.