![Steris Basil 4700 Скачать руководство пользователя страница 163](http://html.mh-extra.com/html/steris/basil-4700/basil-4700_maintenance-manual_1374318163.webp)
7-8
764333-098
which regulate flow of steam and hot water through
heat exchanger as follows:
1. Completely close steam throttling valve and fully
open building hot water supply throttling valve (see
Figure 7-9).
2. Drain chamber sump by selecting DRAIN function
from Manual Menu and pressing
START
touch
pad.
3. After display screen indicates that sump is empty,
select FILL function from Manual Menu and press
START
touch pad.
4. Check reading on heat exchanger temperature
gauge. Gauge indicates temperature of fill water
after water passes through heat exchanger.
5. Slowly open steam throttling valve until tempera-
ture gauge reads desired temperature.
NOTE: Recommended fill water temperature is
180° to 190°F (82° to 88°C).
6. If gauge does not reach desired temperature after
steam throttling valve is fully open, slowly close
building hot water supply throttling valve until
desired temperature is reached.
7.11 HOW TO REPLACE pH CONTROL-
LER
NOTE: pH Controller must be initialized and calibrated
after replacement. See
Section 7.13, How to Adjust pH
AND
Section 7.14, How to Replace pH Sensor
(pH Neutralizing System Option)
WARNING – ELECTRIC SHOCK AND/OR
BURN HAZARD: Disconnect all utilities to
unit before servicing. Do not service unit unless all
utilities have been properly locked out. Always
follow local electrical codes and safety-related
work practices.
1. Lock unit electrical disconnect switch in OFF posi-
tion.
2. Open Main Electrical Box cover and locate pH con-
troller at the bottom of the cover.
3. Disconnect all wires on terminals TB1, TB2 and TB3
on controller.
4. Remove screws on each corner of controller and
remove controller.
5. Install new controller and reconnect all wires on
terminals TB1, TB2 and TB3 at their same location.
Refer to
electrical schematic
#920509-795, in Refer-
ence Drawings Section, if necessary.
7.12 HOW TO CALIBRATE CONTROLLER
OUTPUT SIGNALS
• Material Required:
Loop Calibrator
7.12.1 Conductivity (Channel A)
Install loop calibrator as follows (see Figure 7-10):
a.
Position washer power switch to
OFF
.
b.
Connect loop calibrator to Thornton controller
conductivity output. Make a serial connection.
c.
Ensure loop calibrator is in Read mode (scale
4-20 ma).
d.
Position washer power switch to
ON
.
• Output Calibration:
Washer power switch must be
ON
.
1. Enter in Service Mode as explained in section 2.
2. Press Machine Service touch pad. Screen advances
to Machine Service Screen.
3. Press
CALIBRATION
touch pad.
On Thornton controller:
4. Press
CALIBRATION
button.
Figure 7-9. Heat Exchanger Throttling Valve
Throttling
Valve
Содержание Basil 4700
Страница 1: ...MAINTENANCE MANUAL Basil 4700 Cage and Rack Washer 2008 10 15 P764333 097 ...
Страница 3: ...OPERATOR MANUAL Basil 4700 Cage and Rack Washer 2008 08 14 P920509 645 ...
Страница 87: ...MAINTENANCE MANUAL Maintenance Instructions Basil 4700 Cage and Rack Washer 2008 10 15 P764333 098 ...
Страница 169: ...MAINTENANCE MANUAL IIlustrated Parts Breakdown Basil 4700 Cage and Rack Washer 2008 10 15 P764333 099 ...
Страница 172: ...2 764333 099 Figure 1 Basil 4700 Cage and Rack Washer Inside Washer Inside Inside Washer ...
Страница 174: ...4 764333 099 Figure 2 Cabinet Assembly Left Side Control Shown ...
Страница 176: ...6 764333 099 Figure 3 Sump and Floor Grating Assembly ...
Страница 178: ...8 764333 099 Figure 4 Door Assembly ...
Страница 180: ...10 764333 099 Figure 5 Double Door Interlock System ...
Страница 182: ...12 764333 099 Figure 6 Interior Light ...
Страница 184: ...14 764333 099 Figure 7 Safety Emergency Stop Cable Assembly ...
Страница 186: ...16 764333 099 Figure 8 Spray Header Assembly ...
Страница 188: ...18 764333 099 Figure 9 Cable and Roller Assembly DETAIL A DETAIL B See Detail A See Detail B ...
Страница 190: ...20 764333 099 Figure 10 Traveler Drive and Limit Switch Assembly See Detail A DETAIL B DETAIL A See Detail B ...
Страница 192: ...22 764333 099 Figure 11 Automatic Water Rack Flush System For Two Racks Option ...
Страница 194: ...24 764333 099 Figure 12 Damper 1 ...
Страница 196: ...26 764333 099 Figure 13 Exhaust Fan ...
Страница 198: ...28 764333 099 Figure 14 Hot Water Line Components 6 5 4 10 10 7 8 9 7 ...
Страница 200: ...30 764333 099 Figure 15 Cold Water Line Components ...
Страница 202: ...32 764333 099 Figure 16 Recirculation Piping ...
Страница 204: ...34 764333 099 Figure 17 Steam Line Components ...
Страница 206: ...36 764333 099 Figure 18 Final Rinse System Assembly ...
Страница 208: ...38 764333 099 Figure 19 Recirculation Pump System and Self Cleaning Filter UC DRAIN TANK 1 TANK 2 SPRAY HEADER ...
Страница 210: ...40 764333 099 Figure 20 Pneumatic Block ...
Страница 212: ...42 764333 099 Figure 21 Peristaltic Chemical Injection Pumps ...
Страница 214: ...44 764333 099 Figure 22 Solution Tank 25 ...
Страница 216: ...46 764333 099 Figure 23 Tank Support Frame ...
Страница 218: ...48 764333 099 Figure 24 Guaranteed Cooldown Tank ...
Страница 220: ...50 764333 099 Figure 25a Electrical Box and Control Column Assembly ...
Страница 226: ...56 764333 099 Figure 26 Control Panel See Detail A DETAIL A ...
Страница 228: ...58 764333 099 Figure 27 Seismic Tie Down Anchorage Option ...
Страница 230: ...60 764333 099 Figure 28 Bottle Washing Cart WA02 010 ...
Страница 232: ...62 764333 099 Figure 29 Bottle Washing Cart WA02 020 ...
Страница 234: ...64 764333 099 Figure 30 Pan Cart WA02 030 Accessory ...
Страница 236: ...66 764333 099 Figure 31 Universal Cage and Pan Wash Cart WA03 100 7 ...
Страница 238: ...68 764333 099 Figure 32 Universal Cage Wash Cart WA02 040 ...
Страница 240: ...70 764333 099 Figure 33 Cart Tilt Ramp WA02 050 ...
Страница 242: ...72 764333 099 Figure 34 Floor Ramp for Floor Mounted Units WA02 060 ...
Страница 244: ......
Страница 245: ......
Страница 246: ......
Страница 247: ......
Страница 248: ......
Страница 249: ......
Страница 250: ......
Страница 251: ......
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 256: ......
Страница 257: ......
Страница 258: ......
Страница 259: ......
Страница 260: ......
Страница 261: ......
Страница 262: ......
Страница 263: ......
Страница 264: ......
Страница 265: ......