27
2018 Stenograph, L.L.C. All Rights Reserved.
27
Luminex Captioner/Student User Guide Chapter 4 Writing on the Captioner/Student Edition
·
More
- Increase the key sensitivity when the key is not showing in the steno notes and you want
it to register. Increase the sensitivity using increments of 5. For example, let's say you made the
-T more sensitive using an increment of 5, then 5 displays before the T. It is strongly
recommended that you make the first incremental setting and assess the change. Turn on CNN
or the equivalent and write against the broadcast for 20 - 30 minutes.
·
Less
- Decrease the key sensitivity when the key is showing in the steno notes and is not
wanted. Decrease the sensitivity using increments of 10. For example, if you made the -B less
sensitive using an increment of 10, then -10 displays in red below the B. It is strongly
recommended that you make the first incremental setting and assess the change. Turn on CNN
or the equivalent and write against the broadcast for 20 - 30 minutes.
·
Reset
- Return all the key settings to the factory default.
6. When finished, touch
Done
.
Memory
The Luminex Captioner/Student Edition uses Memory to store steno notes and timestamp files. Steno
note files stored in Memory remain even when you turn the Luminex Captioner/Student Edition Off.
There is 12,000 strokes of Memory on the Luminex Captioner/Student Edition or approximately 50
pages. If the Memory becomes full while writing realtime, the realtime display on the Luminex
Captioner/Student Edition stops scrolling; however, the Luminex Captioner/Student Edition continues
to send steno notes to the CAT system.
View Memory Files
The Memory screen displays the list of files in a year, month, date and time format: 20090716 -
142341 (July 16, 2009 2:23:41 p.m.). By default, the newest file is listed first. The file size and the
estimated number of transcript pages shows for each file. Timestamp files are part of the steno note
file but not visible in the list.
To view Memory files:
1. From the Opening menu, touch
Memory
.
2. Steno note files display with the newest folder first. Use Date Sort to toggle files between
ascending and descending order.
3. Touch the
Up
/
Down
sensors to move to the desired folder and touch
Folder
.
4. A list of files contained in the folder displays with the newest folder first. Use the
Up
/
Down
sensor
and
Date Sort
to view the files.
5. To return to the first Memory screen, touch
Back
.
Содержание Luminex Captioner Student Edition
Страница 1: ......