background image

INSSTE302P0514

17

trouBleshooting

ProbleM

DeFeCTIVe PArT or PArT To CHeCK

The thermostat is hot.

•   In normal operating conditions, the thermostat housing can 

reach nearly 40°C at maximum load. That is normal and will 

not affect the effective operation of the thermostat.

Heating is always on.

•   Check if the thermostat is properly connected. Refer to the 

installation section.

Heating does not run even if the 

thermostat indicates it is on.

•   Check if the thermostat is properly connected. Refer to the 

installation section.

The display does not turn on.

•   Check if the thermostat is properly connected. Refer to the 

installation section. 

•  Check the power supply at the electrical panel. 

•   Check if the heating unit has a switch. If so, ensure that this 

switch is turned on.

The display turns off a few 

minutes and then turns on again.

•   The thermal protection of the heating unit has opened due 

to overheating. Check if the heating unit is in good condition 

of operation and that clearance around the appliance is 

according to the manufacturer’s specifications.

The display has low contrast 

when heating is on.

•   The load is lower than the minimum load. Install a heating 

unit that is within the load limits of the thermostat.

The displayed ambient 

temperature is incorrect.

•   Check the presence of an air stream or a heat source near 

the thermostat, and correct the situation.

The display indicates E1, E2, 

E3 or E4.

•  Faulty thermostat. Contact the customer service.

Weak luminosity of the display.

•   Possibility of a bad contact. Check thermostat wirings. Refer 

to the installation section.

N.B.  If you are unable to solve the problem after having verified these points, please communicate 

with our customer service. Consult our website for the phone numbers.

Содержание STE302PA

Страница 1: ...mation or to consult this guide online please visit our website at www stelpro com User s guide STE302P Multiple programming Electronic thermostat Energy Verified S Y S T M E Q U A L I T C ERTIFI REGI...

Страница 2: ...t this product to a supply source other than 120 VAC or 240 VAC and do not exceed the load limits specified Protect the heating system with the appropriate circuit breaker or fuse You must regularly c...

Страница 3: ...th a resistive load 300 W 240 VAC and 150 W 120 VAC and central heating system Parts supplied one 1 thermostat wall mounting plate located at the back of the thermostat two 2 mounting screws two 2 sol...

Страница 4: ...f the thermostat are clean and clear of any obstruction 3 Using a screwdriver loosen the screw retaining the mounting base of the thermostat until it is loose do not completely remove the screw Then r...

Страница 5: ...them using the supplied solderless connectors When making the connection with aluminum wire make sure that you are using connectors identified CO AL Please note that the thermostat wires do not have p...

Страница 6: ...with those on the mounting base and secure the thermostat to the mounting base Note that you can also position the thermostat on the left or the right side of the junction box Then tighten the screw a...

Страница 7: ...ermostat is initially in degrees Celsius in Preprogrammed mode preprogramming 5 and the Anticipated start mode is activated The clock is adjusted to Saturday 12 00 and flashes to indicate that an adju...

Страница 8: ...ns during 1 minute In case of a power failure lasting less than 2 hours the thermostat saves the adjustment of the hour and the day of the week When the power is restored after an extensive failure th...

Страница 9: ...e it To quickly scroll through the set point values press and hold down the button The standard factory set point adjustment is 21 C From this mode the screen displays the temperature the heating powe...

Страница 10: ...t point temperature of the period is flashing Adjust the set point using the and buttons Confirm your selection by pressing down the button 5 The programming of this period is over The programming of...

Страница 11: ...our the day of the week and the number of the preprogramming period to displayed on the right hand side of the hour This mode is initially activated when the power is turned on for the first time with...

Страница 12: ...observation of the temperature variations in the room and the results obtained during the preceding anticipated starts That way the results should be increasingly precise day after day The icon will b...

Страница 13: ...sired preprogramming Preprogrammed more 1 In any mode Manual Automatic or Preprogrammed out of any adjustment mode press down the button for 3 seconds and release it The various icons and options appe...

Страница 14: ...flashing Press down the button to confirm your choice 5 All icons disappear except the icon that continues to flash Press down the or button to deactivate the Security mode indicated by the icon that...

Страница 15: ...aving and power failures The thermostat saves some parameters in a non volatile memory to be able to recover them after being shut off a power failure for example These parameters are the operation mo...

Страница 16: ...sed to maintain the temperature at the set point is expressed as a percentage indicated by the number of bars in the thermometer displayed The heating power used is displayed as follows 4 bars 76 to 1...

Страница 17: ...isplay turns off a few minutes and then turns on again The thermal protection of the heating unit has opened due to overheating Check if the heating unit is in good condition of operation and that cle...

Страница 18: ...m 10pm 6am 10pm 21 C 70 F 16 5 C 62 F 21 C 70 F 16 5 C 62 F 21 C 70 F 16 5 C 62 F 3 6am 8am 6pm 10pm 6am 10pm 21 C 70 F 16 5 C 62 F 21 C 70 F 16 5 C 62 F 21 C 70 F 16 5 C 62 F 4 7am 9am 4pm 11pm 7am 1...

Страница 19: ...62 F 21 C 70 F 16 5 C 62 F 13 7am 9am 4pm 10pm 7am 10pm 21 C 70 F 16 5 C 62 F 21 C 70 F 16 5 C 62 F 21 C 70 F 16 5 C 62 F 14 7am 9am 5pm 10pm 7am 10pm 21 C 70 F 16 5 C 62 F 21 C 70 F 16 5 C 62 F 21 C...

Страница 20: ...unit has a 3 year warranty If at any time during this period the unit becomes defective it must be returned to its place of purchase with the invoice copy or simply contact our customer service depart...

Отзывы: