16400-7820 GIDOD REV A
11 - FINISHING
A.2 FINISHING THE WALL - USING THE PROVIDED 1/2" STANDOFFS -
EXTERIOR
H - COMBUSTIBLE FRAMING
AND FINSIHING MATERIAL
EXTERIOR
COMBUSTIBLE FRAMING
D - NON-COMBUSTIBLE BOARD OR COMBUSTIBLE
BACKER MATERIAL (I.E. SHEET ROCK/OSB)
B - NON-COMBUSTIBLE BOARD
C. COMBUSTIBLE OR NON-COMBUSTIBLE
FINISHING MATERIAL
E - COMBUSTIBLE MANTEL
F - COMBUSTIBLE HEARTH
I - DECORATIVE FRAME
DO NOT OVERLAP WITH
FINISHING MATERIALS
J- EXTERIOR FLASHING
A. No combustible materials may be within 6” [152mm] of the top of the fireplace.
B. 1/2” [13] CLEARANCE TO COMBUSTIBLES ON SURFACE. The fireplace ships with standoffs in place to ensure a 1/2” [13]
clearance to combustibles is maintained on the surface. See Figure 10A.1. If the standoffs are removed, only non-combustible
material can be installed against the surface of the fireplace such as a non-combustible backer cement board. 1/2” [13] minimum
thickness must be used in the space* between the top of the 3’’ [76] trim to the combustible framing the full width of the fireplace.
The space* includes a 7” [178] minimum above the top of the fireplace that is recommended for ease of attachment. *= 15" [381] for
3'-7' units and 19" [483] for 8' units.See Figure 10A.2
C. Combustible material may cover the non-combustible area mentioned in B.
D. Combustible finishing materials allowed.
E. Combustible mantel may be placed above the top of the decorative glass frame (G) area. There are no restrictions on mantel depth.
F. Combustible hearth may be placed below the bottom of the air in-take vents (F).
G. (EX) Air in-takes run the length of fireplace underneath the decorative frame. They must not be obstructed. You must properly flash
and slope above the hearth so water drains away from the wall.
H. Combustible framing and finishing materials allowed.
I. The 3” [76] surface behind the decorative glass frame (not shown) can not be covered with any type of material. The glass and
decorative frame will be placed on top of this surface. Fasteners must not penetrate the 3” [76] surface.
G (EX) - AIR IN-TAKE VENTS
& FLASHING
= [millimeters]
NOTE: REFER TO DIMENSIONS SECTION FOR ALLOWABLE FINISHING DIMENSIONS REQUIRED TO FIT THE GLASS
PANELS INTO THE FIREPLACE. FINISHING MATERIALS MUST NOT OVERLAP THE DIMENSIONS HIGHLIGHTED IN GREEN ON
PAGE 5. NEVER COVER THE GLASS WITH FINISHING MATERIALS.
NOTE: REFER TO SECTION 5 FRAMING & MANTEL REQUIREMENTS: NON-COMBUSTIBLE ZONE USING PROVIDED 1/2"
STANDOFFS FOR MORE INFORMATION.