The fireplace has standoffs installed on the front of the fireplace standard from the factory. They are located on the left,
center and right front hood of the fireplace and are to ensure that the 1/2" [12.7mm] required clearance to combustibles
on the surface of the fireplace is maintained.
If the standoffs are removed, only non-combustible material can be installed against the surface of the fireplace such
as a non-combustible backer cement board. 1/2” [12.7mm] minimum thickness must be used in the space* between the
top of the 3’’ trim to the combustible framing the full width of the fireplace. The space* includes a 7” [178mm] minimum
above the top of the fireplace that is recommended for ease of attachment. *= 15" [381] for 3'-7' units and 19" [483] for
8' units.
Refer to Figure 5.2 below for requirements when not using the provided 1/2" standoffs.
Refer to Figure 5.1 for a standard installation using the provided 1/2" standoffs.
1/2" [13mm] Standoff
5 - FRAMING & MANTEL REQUIREMENTS
5.2 NON-COMBUSTIBLE ZONE -
NOT
USING THE PROVIDED 1/2" STANDOFFS
NOTE:
Refer to Section 10 (Finishing The Wall)
for more information.
WARNING! Risk of Fire
Comply with all the minimum clearances as specified.
Note About Mantel Depth:
There are no minimum or maximum depth requirements for the mantel.
Notes About TV Placement:
A mantel is not required if you are placing a TV above the opening.
12" [305] minimum clearance requirement for placement of a TV above the opening if NOT using a mantel.
No minimum clearance requirement for placement of TV if using a mantel.