Rotate the handles to the left to put the tool above the workpiece.
When you use an annular cutter, install the cooling system and fill it with coolant.
Do not use only water as the coolant. But you can mix water and drilling oil. Then,
make sure that the cooling system works correctly. To do this, lightly loosen the
bottle cap and use the lever to open the valve. Then, rotate the handles to the left to
apply a light pressure on the pilot pin. The coolant should fill the system and start
flowing from the cutter.
The cooling system works by gravity. Thus, in the horizontal position, rotate the
bottle. In the inverted position, use coolants under pressure or in the form of spray
or paste.
Vertical drilling
Inverted drilling
Horizontal drilling
INCORRECT