Page 16 of 18
939564905 Rev E
®
Finishing the Table Assembly (continued)
Ensure all cables are clear of moving parts.
Before use, the table must be completely leveled,
front-to-back and side-to-side using the height
adjustment glides. Failure to do this could cause
the lifting columns to bind.
Before articulation, you must synchronize the lifting columns as outlined below.
NOTE:
Mounting of CPU and CPU holders: Maximum height for these
units cannot exceed 20-1/2”.
GLIDE
Synchronizing the Lifting Columns
Prior to initial use of the height adjustment function you
must "synchronize the system".
•Press the Down arrow until the worksurface comes to
a stop at the lowest position.
•Release the Down arrow.
•Press and hold the down arrow for approximately 5
seconds while the table synchronizes itself. The surface
will quickly lower itself approximately 5mm, then rise
approximately 5mm and finally settle back to its
lowest position.
After performing this function, the movement of all lifting
columns is synchronized by software inside the control box.
In the unlikely event that an error occurs, reset the control
unit by pressing the Up and Down buttons at the same time
for 5 seconds. Then repeat the synchronizing sequence as
previously outlined above. Refer to the Troubleshooting
Guide if necessary.
Standard
Controller
Digital Desk
Panel Controller
Push Button Stick-On
Controller
14.
11.
23
14.
11.
24
14.
11.
25