25
1.
The table insert (A) must always be level with the
saw table (B). To adjust the table insert, loosen
and remove table insert retaining bolt (C).
SEE FIG. 24.
2.
Place a straight edge across the front and rear of
the table insert. Check that the insert is perfectly
level with the saw table.
3.
To level the table insert, turn the one or more
adjusting set screws (D) as needed and recheck.
4.
Once the insert is level, secure the insert with the
retaining bolt removed in step 1.
5.
The table insert is equipped with a finger hole (E)
for easy removal.
TABLE INSERT ADJUSTMENT
MAKE CERTAIN THAT THE SAW IS DISCONNECT-
ED FROM THE POWER SOURCE.
Fig. 24
C
E
B
D
A
D
D
CHANGING MOTOR VOLTAGE
This section only applies to Model 35600
with the 1-3/4HP Motor. The 35605 Model
with the 3HP motor will only run at 230V.
MAKE CERTAIN THAT THE SAW IS DISCONNECT-
ED FROM THE POWER SOURCE. Have a certified
electrician make all electrical connections. All
local, state and national electric codes must be
followed.
The motor supplied with the table saw is a dual voltage
115/230-volt, single phase motor. The motor is wired
from the factory for 115-volt operation. To change to
230-volt operation for your table saw, proceed with the
following instructions. It is also necessary to replace
the 115 volt plug, supplied with the table saw, with a
UL/CSA Listed plug (not included) suitable for 230 volts
and the rated current of the motor. The table saw with a
230 volt plug should only be connected to an outlet
having the same configuration as the plug. No adapter
is available or should be used with the 230 volt plug.
Fig. 25
A
B
1.
Make sure the switch is “OFF” and disconnect
power cord from power source.
2.
Open motor cover and verify on the motor tag that
motor is dual voltage.
3.
If motor tag states that it is dual voltage remove
junction box cover (A) on motor (B).
SEE FIG. 25.
4.
Using wiring diagram on inside of junction box
cover, reconnect motor leads for 230-volt operation.
5.
Replace junction box cover and close motor cover.
6.
Replace the 115-volt plug with a plug rated for 230-
volt operation.
7.
The ON/OFF switch is 4-pole and does not need
modified.