30
735.794 | 10.10
EN
6 Technical specifications
StecaGrid 300
StecaGrid 500
Input
Input voltage range
45 – 135 V DC
75 – 30 V DC
MPPT range
45 – 100 V DC
75 – 170 V DC
Maximum recommended PV power
375 Wp
65 Wp
Maximum input rating
30 W
(1)
530 W
(1)
Maximum input current
5 A
(1)
5 A
(1)
DC connectors
Multi-Contact MC 3, MC 4
Multi-Contact MC 3, MC 4
(1)
Greater available input power and/or higher available current are not utilised as the inverter contains a protection against over-
load.
Output
Nominal output rating
300 W
500 W
Nominal output voltage / frequency
30 V / 50 Hz
30 V / 50 Hz
Maximum efficiency
94.8 %
95.8 %
European efficiency
93.4 %
94.5 %
Power factor
> 0.95
> 0.95
Harmonic distortion
< 6 % (at maximum power)
< 5 % (at maximum power)
AC connectors
Wieland Electric GST 18i3V
Wieland Electric GST 18i3V
General
Galvanic separation
none
none
Internal power supply
supplied by solar panel
(no Stand-by power)
supplied by solar panel
(no Stand-by power)
Start-up/switching off
Automatic start / stop
Automatic start / stop
Start current
Starts up at > W, 45 V
input voltage
Starts up at > W, 45 V
input voltage
AC monitor
Voltage (30 V +/-10%)
()
Frequency (50 Hz +/- Hz)
()
Voltage (30 V +/-10%)
()
Frequency (50 Hz +/- Hz)
()
Grid monitoring in the
StecaGrid 300 UK or 500 UK versions
Voltage (30 V +/-10 %)
Frequency (50 Hz +0.5 Hz/-3 Hz)
Voltage (30 V +/-10 %)
Frequency (50 Hz +0.5 Hz/-3 Hz)
Grid monitoring in the
StecaGrid 300 ES or 500 ES versions
Voltage (30 V +10 %/-15 %)
Frequency (50 Hz +/-1 Hz)
Voltage (30 V +10 %/-15 %)
Frequency (50 Hz +/-1 Hz)
Anti-islanding protection
Voltage and frequency window
monitoring; ENS optional with
StecaGrid ENS6
Voltage and frequency window
monitoring; ENS optional with
StecaGrid ENS6
Dimensions (X x Y x Z)
176 x 43 x 71 mm
176 x 43 x 71 mm
Weight
1.4 kg
1.4 kg
()
Other limit settings are also available ex works
Environmental conditions
Temperature
-0 °C to 45 °C
-0 °C to 45 °C
Installation
Indoors (protection class IP 0)
Indoors (protection class IP 0)
Installation and connection
Installation of a single inverter
Three fixing screws
Installation of two and more inverters
DIN rail
Interconnection AC side
AC connector (Wieland Electric GST 18i3V 1P1)
(3)
(3)
The coupler plug is supplied with the inverter.