This window monitors also battery voltage (13,7) as well as charge current (+04.3) and the discharge
current (-12.4) with more accurate values.
5 Operating The System-Manager
5.1 Safety Cover
The safety cover is a plastic lid covering the programming keys and safety fuses. The lid can be removed if desired. In
order to avoid undesired modification of important settings, however, it is recommended that the lid be left on the System-
Manager. Intentionally, the lid is designed to be difficult to open. This is to prevent unwanted changes from being easily
made. The lid can be easily opened with following trick.
Hint: To open the cover, using your left-hand, stick your fingernail into the slot, move it along the slot and pull open the
cover.
When putting the lid on the case again, please make sure to put the turning joint into the case first and then into the
snap-in hole.
Using one of the option you can break the rated point on the left side.
5.2 Main Menu
Pressing the MENU button you will
enter into
the menu. With the arrow keys
▲▼
you
can scroll through the menu items,
but no
values appear and no parameters
can be
changed by this scrolling action. To
enter into a
selected window press OK.
System-Manager TAROM | 716148
page 8
V09_45A
⇒
With the arrow keys
▲▼
you
can
scroll through the menu items,
but no
values appear and no
parameters can be changed by
this
scrolling action.
⇒
By pressing OK the displayed
menu
window is activated, and the
value is
indicated. Pressing OK once again leads to a closure of the window without adjustment.
⇒
After a menu window is activated and its value is displayed, use the arrow keys
▲▼
to can change the value. When
the maximum value has been reached, the parameter starts at the lowest value again. By constantly pressing the key,
the value starts to scroll in small steps.
⇒
Confirmation and storage of the new value is done by pressing OK
⇒
if no selection of another menu is made within 5 seconds after OK is pressed, the System-Manager will automatically
exit from all menus and the normal indication of running status appears .
⇒
If there are no adjustments for 2 minutes on an activated submenu value being changed, the display indication jumps
to the main menu and the adjustment in the open window is not stored or applicable.
⇒
The MENU key will bring the display back to the status indicator display.
5.3 Sub Menu
Here you have the possibility to directly influence the System-Manager’s behaviour
Within this window, the load can manually be connected or disconnected. By pressing OK you enter
this window and you may then switch
▲▼
from “load on“ to “load off“ or ”auto“. However, the battery will still be
protected from the worst discharge by an emergency cut-off that cannot be overridden by the manual control function.
“load off“ switches off all loads and may be used as main switch if you leave your solar system for a longer period of