75
742.221 | 12.04
EN
14
Technical data
14.1
Inverter
StecaGrid 3000
StecaGrid 3600
DC input side (PV generator connection)
Maximum start voltage
845 V
Maximum input voltage
845 V
Minimum input voltage
350 V
Startup input voltage
350 V
Rated input voltage
380 V
455 V
Minimum input voltage for rated
output
350 V
365 V
MPP voltage
350 V … 700 V
Maximum input current
10 A
Rated input current
8 A
Maximum input power (cos
φ
= 1)
3060 W
3690 W
Rated input power (cos
φ
= 1)
3060 W
3690 W (Portugal: 3540 W)
Recommended maximum PV output
3800 Wp
4500 Wp
Derating / power limiting
occurs automatically when:
•
input power > max. recommended PV power
•
cooling is inadequate
•
input current > 10 A
•
grid current > 16 A
AC output side (mains grid connection)
Output voltage
185 V ... 276 V (depending on the country settings)
Rated output voltage
230 V
Maximum output current
16 A
Rated output current
13 A
15.6 A
Maximum active power (cos
φ
= 1)
3000 W
3600 W (Belgium: 3330 W)
Maximum active power (cos
φ
= 0.95)
3000 W
3530 W
Maximum apparent power (cos
φ
= 0.95)
3130 VA
3680 VA
Rated output
3000 W
3600 W (Portugal: 3450 W)
Rated frequency
50 Hz and 60 Hz
Grid type
L / N / PE (protective earth )
Grid frequency
45 Hz ... 65 Hz (depending on the country settings)
Power losses in nighttime operation
< 0.9 W
Feeding phases
single-phase
Distortion factor (cos
φ
= 1.00)
< 2 %
Power factor cos
φ
0.95 capacitive ... 0.95 inductive
Characterisation of the operating behaviour
Maximum efficiency
98.6 %
European efficiency
98.2 %
98.1 %
MPP efficiency
> 99.7 % (static), > 99 % (dynamic)
Efficiency values (at 5 %, 10 %, 20 %,
25 %, 30 %, 50 %, 75 %, 100 % of
the rated power) at rated voltage
95.3 %, 97.2 %, 98.2 %,
98.4 %, 98.5 %, 98.4 %,
98.2 %, 97.9 %
95.1 %, 97.0 %, 98.2 %,
98.3 %, 98.3 %, 98.3 %,
97.9 %, 97.5 %
Efficiency values (at 5 %, 10 %, 20 %,
25 %, 30 %, 50 %, 75 %, 100 % of
the rated power) at minimum MPP
voltage
95.5 %, 97.4 %, 98.4 %,
98.5 %, 98.6 %, 98.6 %,
98.3 %, 97.9 %
95.5 %, 97.4 %, 98.5 %,
98.6 %, 98.6 %, 98.4 %,
98.1 %, 97.6 %
Efficiency values (at 5 %, 10 %, 20 %,
25 %, 30 %, 50 %, 75 %, 100 % of
the rated power) at maximum MPP
voltage
93.9 %, 95.9 %, 97.3 %,
97.6 %, 97.7 %, 97.9 %,
97.7 %, 97.4 %
93.9 %, 95.9 %, 97.6 %,
97.7 %, 97.8 %, 97.8 %,
97.6 %, 97.1 %
Содержание coolcept StecaGrid 3000
Страница 127: ...125 742 221 12 04 Appendix Zertifikate Certificates Certificats...
Страница 128: ...126 742 221 12 04 Appendix...
Страница 129: ...127 742 221 12 04 Appendix...
Страница 130: ...128 742 221 12 04 Appendix...
Страница 131: ...129 742 221 12 04 Appendix...
Страница 132: ...742221...