Page 14 of 19
MAINTENANCE
Warning Indicators
There are three LED lights on the top of the machine: for battery, fluid levels and rinse setting:
Battery:
During normal use and when the battery is being charged the battery LED will be a
solid red. When there is 10% or less charge left in the battery the LED will flash
continually, indicting a charge is required.
Fluid:
The fluid LED will illuminate solid red when the fluid reservoir is empty. The power
will automatically be cut when the fluid reservoir is empty.
Rinse:
The rinse LED will illuminate solid red when the machine is operated in the ‘R’
setting. The rinse LED will flash continually after 50 days of no activity or 100 hours
of use to indicate that a descale is required.
All three lights will flash together
of the heating cartridge reaches more than 160
C (320
F) or if
the heating unit is not correctly attached.
To Reset this error code, first:
1. Turn off both power switches
2.
Set the flow switch to ‘R’.
3. Turn both power switches on
4. After seeing fluid run for at least 10 seconds turn the flow
dial to either
•
or
••
If the three lights are still flashing:
1. Turn off both power switches
2. Disconnect all extension poles from the machine,
including the heater unit.
3. Re-attach each extension pole and the heater unit
making sure that each connector is aligned correctly.
4.
Set the flow switch to ‘R’.
5. Turn both power switches on
6. After seeing fluid run for at least 10 seconds turn the flow
dial to either
•
or
••
Descaling
The internal heating element can have a build-up of lime-scale due to the operating temperature and
a variety in water hardness. The rinse LED will flash continually after 50 days of no activity or 100
hours of use to indicate that a descale is required.
Only use the Steam-e® descale solution to prevent damage to the Gum Remover.
Never use setting
•
or
••
when running descale solution as this can cause serious harm if inhaled.
Only use setting
‘R’ when running descale solution and be certain to follow the instructions on the
descale solution and make sure you have read and fully understand the Material Data Safety Sheet
instructions.