– 50 –
*1 ASB Function
When this function is enabled, status information is automatically sent to the host whenever the
printer status changes (such as when the cover is opened, paper runs out, or an error occurs).
For information about automatic status information transmission, refer to the separate Program-
mer's Manual (Star Line Mode and ESC/POS Mode).
*2 NSB Function
When this function is enabled, status information is sent automatically whenever the printer
enters into reverse forwarding mode.
For information about automatic status information transmission, refer to the separate Program-
mer's Manual (Star Line Mode)
DIP-SW 2
Switch
Function
ON
OFF
2-1
Always ON
Should be set to on
2-2
2-3
2-4
The factory settings of DIP switch are all on.
■
Initializing Settings
Set the push switch as described below to initialize the
setting information.
Push the switch for one to five seconds while running
under normal operating mode. The green and red LEDs
will flash with a regular pattern. After that, push the
switch once again in that state to turn OFF both of the
red and green LEDs. This will return the settings of
the interface board to their default, or ex-factory, set-
tings. After the interface board has been initialized, the
printer will automatically reboot itself.
■
LED Display
Green : Lights when other party connection is
recognized as 100BASE-TX.
Red :
Lights when packets are received.
Push Switch
LED