-6-
2 DIP Switch Bank
(Auxiliary AND Park-Kill Input Polarity)
On the back of the siren, in the upper left
hand corner, you will find an opening that
allows you access to 2 DIP switches that allow
you to change whether your Auxiliary and
Park Kill inputs are positive or negative.
The Auxiliary input (terminal #7) and Park Kill input (terminal
#12) are normally activated by applying a positive voltage
to the appropriate terminal. If you would like to activate
either function by connecting it to ground (negative) instead,
use the DIP switches located on the back of the siren.
The default setting for both switches (Positive Switching) is
such that the DIP switches are flipped AWAY from the closest
edge of the siren
(i.e. DOWN in the picture to the right)
. To
have either function activated when the input is grounded,
flip the corresponding switch in the opposite direction
(TOWARDS the edge of the siren).
NEG
POS
P
/K
P
O
LA
R
IT
Y
A
U
X
P
O
LA
R
IT
Y
Installer Selectable Options
DIP Switch Settings:
There are two banks of DIP switches that control various options on this siren, a bank
of 7 switches and a bank of 2 switches.
7 DIP Switch Bank
While facing the siren, on the left side of the
box you will find an opening that allows you
access to 7 DIP switches.
Please review the functions of each below:
1
Slide Switch
also activates
.
(default=ON)
2
Slide Switch
also activates
.
(default=ON)
3
Slide Switch
also activates
.
(default=ON)
4
Slide Switch
activates Wail tone.
(default=OFF)
5
Slide Switch
activates Wail tone.
(default=OFF)
6
Slide Switch
activates Wail tone.
(default=ON)
7
Siren Backlighting only comes on with
On/Off PA volume knob.
(default=OFF)
Flip the DIP switch accordingly to change any of the options. Towards the number
ENABLES the option, away from the numbers DISABLES the option. The default
switch positions are shown in the picture above.