Fig.11
MATERIALS
(see figs 11, 12, 13, 14)
Back wall
6” (150mm)
Left side wall looking from front
5” (125mm)
Right side wall looking from front
5” (125mm)
Alcove or mantle from top of unit
18” (459mm)
From Corner
5” (125mm)
Fig.12
Fig.13
Fig.14
When installing the stove against a
combustible wall leave a 6” space
between the back of the stove and
the wall for air circulation.
(See Fig.12)
Fig.15
When installing the stove against a
non-combustible wall leave a 2” space
between the back of the stove and the
wall for air circulation. (See Fig.15)
HEARTH FITTING
This stove MUST be installed on a concrete con-
structional hearth, or on a non-combustible hearth
slab, minimum size 27.5” (500mm) x 28.8”
(732mm) deep with the fire place opening central-
ly located. The hearth material should be at least
13mm (1/2”) thick, the top surface being prefer-
ably 50mm (2”) above floor level to discourage the
placing of carpets over it. (see fig.16)
Fig.16
6