Stanley OISIN MK II Скачать руководство пользователя страница 3

OPERATION INSTRUCTIONS

WARNING:

Do not operate the stove with the

appliance door open, or if the glass panel in the
front door has been broken or removed.  Ensure
that the door latch is fully locked.  Keep the door
spin valve closed at all times when stove is in
operation.

PRECAUTIONS

1.

Do not touch any part of the stove while in
operation, except the controls.

2.

Children and adults should be alerted to 
the hazards of surface temperatures.

3.

Guards may be required to take account of
the special hazards that exist in nurseries
and other places where there are young 
children, aged or infirm persons.

4.

Curtains or other combustible material 
should not be positioned on/or above the 
appliance at a distance less than 38” 
(965mm).

5.

Do not use this appliance if any part has 
been under water, immediately call a qual-
ified service technician to inspect the appli-
ance and to replace any part of the gas 
control or system which has  been under 
water.

6.

Do not store gasoline or other flammable 
liquids having flammable vapours near this
stove.

7.

Tools must not be used to turn or operate 
the valve control knob.

8.

Use only in a sufficiently ventilated space.

9.

This appliance must be installed in accor-
dance with the rules in force.

10.

Read the label and manual provided 
before commencing to install or attempting
to operate the stove.  

Failure to do so may result in property 
damage or personal injury.

LIGHTING

1.

The stove control knob is located at  the 
bottom right hand side looking from the 
front.

2.

The valve is in the off position when the 
control knob symbol “OFF” is at the datum
point and there is no gas to the pilot or 
main burner.  The knob can only be turned
in a clockwise direction to reach the “OFF”
position. (see fig.1)

Fig. 1

3.

Press the control knob all the way in and 
turn anti-clockwise until you hear a clicking
sound.

4.

Keep the control knob pressed for 15-30 
seconds, and then release .  If the pilot 
fails to remain lighting repeat this action.

5.

With the pilot burner lighting, to establish 
the flame hold the control knob in the fully
pressed position with dot pointing towards
ignition.  (see fig. 2)

Fig. 2

6.

To light the main burner, fully release 
the control knob and turn anti-clock-wise to
the required setting.  (see figs. 3&4)

2

High Flame Setting

Fig. 3

Содержание OISIN MK II

Страница 1: ...stalled by a suitably qualified and competent person This appliance is hot while in operation and retains its heat for a long period of time after use Children aged or infirm persons should be supervi...

Страница 2: ...4 Use of Existing Chimney s and Flues 7 15 Factory Made Insulated Chimneys 8 16 Ventilation Combustion Air Requirements 8 17 Gas Pipes Fittings 8 18 Meters 8 19 Pipe Size 8 20 Connection to Gas Supply...

Страница 3: ...stove 7 Tools must not be used to turn or operate the valve control knob 8 Use only in a sufficiently ventilated space 9 This appliance must be installed in accor dance with the rules in force 10 Rea...

Страница 4: ...building F Immediately call your gas engineer from a neighbours phone G If you cannot reach your gas supplier call the Fire Department VENT SAFETY SHUT OFF SWITCH The vent safety shut off switch loca...

Страница 5: ...burners and circulating air passageways of the room heater are kept clean NOTE Before installation check that the local distribution conditions nature of gas and pres sure and adjustment of the applia...

Страница 6: ...ar flue outlet The stove has a rear flue outlet configuration factory fitted It may be changed to a top flue outlet by simply switching the blanking cap and flue collar as shown in Fig 8 9 Fig 7 Fig 8...

Страница 7: ...ion See Fig 12 Fig 15 When installing the stove against a non combustible wall leave a 2 space between the back of the stove and the wall for air circulation See Fig 15 HEARTH FITTING This stove MUST...

Страница 8: ...ng to B S 4543 a galvanised finish is not suit able Clay flue linings conforming to I S 51 B S EN 1457 1999 Pre cast concrete chimney blocks incor porated into the building structure It is particularl...

Страница 9: ...there is another combustion appliance fitted in the same or adjacent room it will be necessary to refer to the rules in force to calculate the additional air supply If there is an air extraction fan f...

Страница 10: ...warranty Fig 21 WARNING To avoid pipe sealing compounds from entering into the gas train do not apply seal ing compound to the first two threads at the tip of the gas connection Fig 22 Fig 23 NOTE Cl...

Страница 11: ...5 4 Place 4 medium coals on the front of the matrix with their corners touching and also one corner of each coal resting on a spar see Fig 26 Fig 26 6 Place 3 small coals on 3 of the medium coals leav...

Страница 12: ...il the odour has gone BURNER LIGHTING 1 With the pilot flame firmly established turn the control knob anti clockwise to the high position When the main burner is lighting adjust control knob clockwise...

Страница 13: ...switch located at the back of the stove See Fig 33 6 Under the two M6 wing nuts located on the under side of the stove on the right and on the left See Fig 33 7 Carefully lift up the burner assembly s...