IMPORTANT:

Please ensure that the pilot injec-

tor is clear at all times, as a partially blocked injec-
tor will result in a reduced flame which may be
insufficient for ignition purposes.

MAINTENANCE

CAUTION:

Maintenance of this stove should only

be carried out by a qualified/competent Gas
Engineer.

Isolate the main gas supply before carrying
out any maintenance.

Removal of Burner

1.

Shut off gas supply at the shut off valve.

2.

Open door (item 9).

3.

Carefully remove the coals.

4.

Disconnect the 8mm gas pipe at the back
of the control under the lip.  (see Fig.32)

12

Fig.32

5.

Disconnect the snap switch leads from the
snap switch located at the back of the 
stove.  (See Fig. 33).

6.  Under the two M6

wing nuts located on
the under side of the 
stove on the right and
on the left.  (See Fig.  
33).

7.  Carefully lift up the

burner assembly start
ing with the left side 
and gradually turning
the assembly anti-
clockwise until the left 
side of the assembly
is facing towards the
door opening.  (See     
Fig.35, 36, 37).

Fig.33

Fig.34

Fig.35

Fig.36

Fig.37

Fig.38

Changing of Burner Injector Orifice

With the complete burner assembly removed as
per Fig. 36, 37, 38.

1.

Disconnect the 6mm gas feed pipe from 
the control to injector.  (see Fig. 39).

2.

Slacken the 6mm gas feed pipe to the
injector at the control.

3. 

Remove Injector from burner.

Removal of Pilot Burner

1.

Unscrew the two 

1

/4

” slotted head screw 

from pilot burner.  (See Fig.39)

2.

Disconnect the 6mm gas feed pipe.

Fig.39

Содержание OISIN MK II

Страница 1: ...stalled by a suitably qualified and competent person This appliance is hot while in operation and retains its heat for a long period of time after use Children aged or infirm persons should be supervi...

Страница 2: ...4 Use of Existing Chimney s and Flues 7 15 Factory Made Insulated Chimneys 8 16 Ventilation Combustion Air Requirements 8 17 Gas Pipes Fittings 8 18 Meters 8 19 Pipe Size 8 20 Connection to Gas Supply...

Страница 3: ...stove 7 Tools must not be used to turn or operate the valve control knob 8 Use only in a sufficiently ventilated space 9 This appliance must be installed in accor dance with the rules in force 10 Rea...

Страница 4: ...building F Immediately call your gas engineer from a neighbours phone G If you cannot reach your gas supplier call the Fire Department VENT SAFETY SHUT OFF SWITCH The vent safety shut off switch loca...

Страница 5: ...burners and circulating air passageways of the room heater are kept clean NOTE Before installation check that the local distribution conditions nature of gas and pres sure and adjustment of the applia...

Страница 6: ...ar flue outlet The stove has a rear flue outlet configuration factory fitted It may be changed to a top flue outlet by simply switching the blanking cap and flue collar as shown in Fig 8 9 Fig 7 Fig 8...

Страница 7: ...ion See Fig 12 Fig 15 When installing the stove against a non combustible wall leave a 2 space between the back of the stove and the wall for air circulation See Fig 15 HEARTH FITTING This stove MUST...

Страница 8: ...ng to B S 4543 a galvanised finish is not suit able Clay flue linings conforming to I S 51 B S EN 1457 1999 Pre cast concrete chimney blocks incor porated into the building structure It is particularl...

Страница 9: ...there is another combustion appliance fitted in the same or adjacent room it will be necessary to refer to the rules in force to calculate the additional air supply If there is an air extraction fan f...

Страница 10: ...warranty Fig 21 WARNING To avoid pipe sealing compounds from entering into the gas train do not apply seal ing compound to the first two threads at the tip of the gas connection Fig 22 Fig 23 NOTE Cl...

Страница 11: ...5 4 Place 4 medium coals on the front of the matrix with their corners touching and also one corner of each coal resting on a spar see Fig 26 Fig 26 6 Place 3 small coals on 3 of the medium coals leav...

Страница 12: ...il the odour has gone BURNER LIGHTING 1 With the pilot flame firmly established turn the control knob anti clockwise to the high position When the main burner is lighting adjust control knob clockwise...

Страница 13: ...switch located at the back of the stove See Fig 33 6 Under the two M6 wing nuts located on the under side of the stove on the right and on the left See Fig 33 7 Carefully lift up the burner assembly s...

Страница 14: ...y damp cloth followed by a polish with a clean dry duster 2 For stubborn deposits a soap impregnated pad can be carefully used on the vitreous enamel 3 Use only products recommended by the Vitreous En...

Страница 15: ...s Call your qualified service technician Incorrect inlet pressure Call your qualified service technician Blocked orifice Call your qualified service technician Faulty control valve Call your qualified...

Страница 16: ...pable of producing a continuous draught of between 0 06 w g during normal operation Location 1 Clearance to combustible materials must be adhered to as described in the Clearance to Combustibles secti...

Отзывы: