Turning the knob “MENU”, it is possible to select the type and diameter of the electrode, the manual mode. The display will show the
corresponding selection.
Electrode selection
Once you have selected the type and diameter of the electrode, the onboard computer self adjusts the configuration by selecting the
corresponding value of current to obtain the best welding. The display shows, first, the electrode selected and then the current self-
regulated.
Rutile electrode selection
basic electrode selection
Stainless steel electrode
selection
Cast iron electrode selection
where rX.X is the rutile electrode with diameter X.X
MANUAL selection
When the manual mode is selected, the display will show "Man"; the self-regulation of
welding current is disabled. The user can select the desired setting
SUPPLY SISTEM ANALYSIS
At each turn on, the machine analyzes the electrical network by performing the check of the supply voltage (SAFETY POWER) and the
verification of the presence of the grounding system (SAFETY USER).
MAINS ANALYSIS
At each turn on, the machine analyzes the electrical network checking the supply voltage (SAFETY POWER) and the grounding system
(SAFETY USER).
USER SAFETY
At each turn on, the machine scans the electrical grid to check if the system is equipped with grounding system. The outcome of the
verification is stored on its internal memory. The purpose is to ensure the user safety . In case of negative outcome, the user will push the
knob "MENU" to continue using the welder. The event will be stored in the memory and the data can be retrieved from a service centre.
SAFETY POWER
At each turn on, the machine performs the check of the supply voltage.
When the voltage supply is less than 165V, the machine go in protection mode and it not allow to weld
until the voltage supply is not within the allowed limits, the display will show "LO"