background image

8

9

OVERVIEW

Common Actions and Unit Responses

The following actions turn the unit on and activate the LCD screen:

Press the Battery Status Button.

(Refer to the "Viewing Battery Status" 

section.)

A beep will sound and the backlit LCD screen will display the Battery Status  

Icon and Battery Voltage Indicator for 10 seconds before the unit automatically 

turns off.

Press the Alternator Check Button.

(Refer to the "Alternator Check" 

section.)

A beep will sound and the backlit LCD screen will display the Battery Status 

Icon, and the Alternator Icon will flash. The unit remains on until the Alternator 

Check Button is pressed again to turn it off. 

Press the LED Area Light Power Button.

(Refer to the "LED Area Light" section.)

A beep will sound and the Area Light will turn on. The backlight will turn on for 

10 seconds (only). The LCD screen will continue to display the Battery Status  

Icon and Battery Voltage Indicator. The unit remains on until the LED Area Light 

Power Button is pressed again to turn it off.

Press the USB Power Button. 

(Refer to 

the "USB Ports" section.)

A beep will sound and the backlit LCD screen will display the Battery Status  

Icon and Battery Voltage Indicator, as well as the USB Icon, indicating the 4 USB 

Ports are available. The unit remains on until the USB Power Button is pressed 

again to turn it off.

Press the Compressor Power Button. 

(Refer to the "Portable Compressor" 

section.)

A beep will sound and the backlit LCD screen will display the Battery Status  

Icon, "XXX" PSI and the Compressor Icon. If no further actions are taken after 

1 minute, the unit will display the Battery Status Icon and Battery Voltage 

Indicator for 10 seconds before automatically turning off.

Whenever the clamps are properly 

connected to a battery

 (refer to the 

"Jump Starter" section) 

… 

… a beep will sound and the backlit LCD screen will display the Battery Status  

Icon, Battery Voltage Indicator, the Clamp Icons, and the “+” and”–” signs, as 

well as the flashing Jump Starter Icon. The unit remains on until the clamps are 

disconnected from the battery.

If the Jump Starter Power Switch is 

rotated to the on position and the 

clamps are not connected to a battery

 

(refer to the "Jump Starter" section)

 …

... a two-second warning will sound every 10 seconds. The backlit LCD screen will 

display the Battery Status Icon, Battery Voltage Indicator, the Clamp Icons, and 

the “+” and ”–” signs. The Alarm Icon and the Jump Starter Icon will flash. The 

unit remains on until the Jump Starter Power Switch is switched off and then 

displays the battery status icon and the voltage of digital display for 10 seconds 

before automatic shut down.

If the clamp connections to the 

battery’s positive and negative 

terminals are reversed

 (refer to the 

"Jump Starter" section) 

… the backlit LCD screen will display the Battery Status Icon, Battery Voltage 

Indicator, and the Clamp Icons. The Alarm Icon, the “+” and ”–” signs and the 

Arrow Icons will flash and the unit will sound a warning continuously until the 

clamps are disconnected from the battery.

When the unit is charging or  

recharging using the built-in 120 Volt 

AC Charger 

(refer to the "Charging/

Recharging" section) 

… a beep will sound and the backlight will turn on for 10 seconds (only). The 

LCD screen will continue to display the Battery Status Icon and Battery Voltage 

Indicator. The bars on the Battery Status Icon will change from empty to solid 

(bottom to top) repeatedly.

Note:

  The unit will automatically power off once ALL the functions are turned off.

VIEWING BATTERY STATUS

To check the unit’s battery charge level, press the Battery Status Button. The Battery Status Icon and Battery Voltage Indicator 

will display for 10 seconds (only), indicating the battery charge level as follows.

• If the battery charge level is at full capacity, four solid bars will display.

• If the battery is partially charged, two or three solid bars will display.

• If the battery is nearly empty, one solid bar will display. The unit should be charged at this time.

• If the battery is completely empty, four blank bars will display. The unit MUST be charged at this time or the unit’s built-in 

low voltage protection will activate. The empty Battery Status Icon will flash for a short period of time before automatic shut 

down. The unit will not operate until the battery is recharged.

Note: 

If no other actions are taken, the unit will automatically power off after 10 seconds.

CHARGING/RECHARGING

Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. All batteries lose energy from self-  

discharge over time and more rapidly at higher temperatures. Therefore, batteries need periodic charging to replace energy lost 

through self-discharge. When the unit is not in frequent use, manufacturer recommends the battery should be recharged at least every 

30 days and after each use.

Notes: 

This unit is delivered in a partially charged state – you must fully charge it before using it for the first time. Initial AC charge should be for 40 hours or 

until the Battery Status Icon shows 4 solid bars.

 

Recharging the battery after each use will prolong battery life; frequent heavy discharges between recharges and/or overcharging will reduce battery life.

 

The battery can be recharged using the built-in 120 Volt AC Charger.

 

Make sure all other unit functions are turned off during recharging, as this can slow the recharging process.

CAUTION: RISK OF PROPERTY DAMAGE: 

Failure to keep the battery charged will cause permanent damage and result in 

poor jump starting performance.

IMPORTANT:

 If you know the unit is discharged, but the battery icon displays four solid bars as if the unit is fully charged when 

connected to a charging power source, this may be due to the internal battery having high impedance. The manufacturer 

suggests leaving the unit charging for a period of 40 hours using the built-in AC charger before use. 

Charging/Recharging Using the Built-In 120 Volt AC Charger and AC Extension Cord

 1. Lift the protective cover of the built-in 120 volt AC charger located on the lower left front of the unit (refer to the 

"Features" section to locate). Connect an extension cord to the unit. Plug the other end of the cord into a standard 120-volt 

AC wall outlet. When the unit is properly connected to an AC power source, the LCD screen will display the following:

  The bars on the Battery Status Icon represent the charge level of the unit’s internal battery. The bars on the Battery Status 

Icon will change from empty to solid (bottom to top) repeatedly to indicate the unit is charging. The backlight will turn on 

for 10 seconds (only).

 2. Charge for approximately 40 hours or until the Battery Status Icon shows 4 solid bars.

 3. When charging is complete, unplug the AC extension cord from the AC outlet and then disconnect it from the unit.

JUMP-STARTER

This unit is equipped with a jump starter power switch that allows energy to flow only when proper connections are made to 

battery and frame. 

a) For negative-grounded systems, connect the positive (red) clamp to the positive ungrounded battery post and the negative 

(black) clamp to the vehicle chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel 

lines or sheet-metal body parts. Connect to a heavy gage metal part of the frame or engine block.

b) For positive-grounded systems, connect the negative (black) clamp to the negative ungrounded battery post and the 

positive (red) clamp to the vehicle chassis or engine block away from the battery. Do not connect the clamp to the 

carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gage metal part of the frame or engine block.

IMPORTANT: 

Make sure the Compressor Power Button has been turned off before attempting to use the unit as a Jump Starter.

WARNING: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:

• 

FOLLOW ALL SAFETY INSTRUCTIONS FOUND IN THE “Specific safety instructions for jump starters” section of this 

instruction manual.

• Never touch red and black clamps together — this can cause dangerous sparks, power arcing, and/or explosion.

• If the clamps are connected incorrectly with regard to polarity, the unit will sound a continuous alarm until the clamps are 

disconnected. The backlit LCD Screen will display the Battery Status Icon, the Battery Voltage Icon and the Clamp Icons. The 

PP1DCS_ManualENSP_072116.indd   8-9

7/27/2016   10:20:07 AM

Содержание PP1DCS

Страница 1: ...L PROFESIONAL MANUAL DE INSTRUCCIÓN SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE CONSERVE ESTE MANUAL PARA FUTURAS CONSULTAS 2016 Baccus Global LLC Boca Raton FL 33432 877 571 2391 PP1DCS English page 3 Español pagina 16 BC PP1DCS_ManualENSP_072116 indd 32 1 7 27 2016 10 20 05 AM ...

Страница 2: ...se instala y se usa de acuerdo con las instrucciones puede provocar interferencia perjudicial en las comunicaciones de radio Sin embargo no hay garantía de que la interferencia no ocurra en una instalación en particular Si el equipo provoca interferencia perjudicial en la recepción de radio o televisión lo que se puede determinar al apagar y encender el equipo el usuario debe tratar de corregir la...

Страница 3: ...y be used for this measure of safety Use of accessories and attachments The use of any accessory or attachment not recommended for use with this appliance could be hazardous Refer to the accessory section of this manual for further details Stay alert Use common sense Do not operate this equipment when you are tired or impaired Check for damaged parts Any part that is damaged should be replaced by ...

Страница 4: ...ilated area Always store battery clamps when not in use Never touch battery clamps together This can cause dangerous sparks power arcing and or explosion When using this unit close to the vehicle s battery and engine stand the unit on a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving vehicle parts Never allow red and black clamps to touch each othe...

Страница 5: ...it s built in low voltage protection will activate The empty Battery Status Icon will flash for a short period of time before automatic shut down The unit will not operate until the battery is recharged Note If no other actions are taken the unit will automatically power off after 10 seconds CHARGING RECHARGING Lead acid batteries require routine maintenance to ensure a full charge and long batter...

Страница 6: ...operly the unit will automatically turn on in jump starter mode The backlit LCD screen will display the following to indicate the unit is ready to jump start The Battery Status icon Battery Voltage Indicator Clamp Icons and the and signs light solid The jump starter icon will flash to indicate the clamps are properly connected 7 Turn the Jump Starter Power Switch on Turn on the ignition and crank ...

Страница 7: ...age the compressor If the compressor must be operated for longer periods every 10 minutes press the Compressor Power Button to turn the compressor off then restart after a cooling down period of approximately 30 minutes Inflating Tires or Products With Valve Stems 1 Screw the SureFit nozzle onto the valve stem Do not overtighten 2 Press the Compressor Power Button A beep will sound and the backlit...

Страница 8: ... clean the outer surfaces of the unit with a soft cloth moistened with a mild solution of water and detergent There are no user replaceable parts Periodically inspect the condition of adapters connectors and wires Contact manufacturer to replace any components that have become worn or broken Battery replacement disposal BATTERY REPLACEMENT The battery should last the service life of the unit Servi...

Страница 9: ...s graves ADVERTENCIAS E INSTRUCCIONES DE SEGURIDAD GENERALES ADVERTENCIA Este producto o su cable de alimentación contiene plomo una sustancia química reconocida por el Estado de California como causante de cáncer defectos de nacimiento u otros problemas reproductivos Lávese las manos después de utilizarlo Esta unidad fue diseñada para el uso domestico ADVERTENCIA RIESGO DE INCENDIOS DESCARGAS ELÉ...

Страница 10: ...ara el caso de contacto accidental con el ácido de la batería Tenga al alcance mucha agua potable y jabón en el caso de que el ácido de la batería entre en contacto con la piel Nunca fume o permita que haya una chispa o llama cerca de la batería el motor o la central de energía Manténgase alejado de las paletas de ventilador correas poleas y otras partes que pueden provocar lesiones a las personas...

Страница 11: ...tería muestra durante 10 segundos antes de apagado automático Si se invierten las conexiones de pinza de bornes positivo y negativo de la batería consulte la sección Puente auxiliar de arranque la pantalla LCD retroiluminada mostrará el icono de estado de la batería el indicador del voltaje de la batería y el icono de pinzas El icono de alarma el signos y y los iconos de flecha parpadearán y la un...

Страница 12: ... y luego el cable del puente del positivo rojo excepto para los sistemas con positivo a tierra Procedimiento Tome las medidas siguientes observando todas las precauciones y advertencias en la sección de las instrucciones de seguridad importantes en el frente de este manual 1 Apague la ignición del vehículo y todos los accesorios radio aire acondicionado luces cargadores de teléfono celular conecta...

Страница 13: ...o libre de la manguera del compresor La manguera del compresor con montaje de los neumáticos se almacena en el compartimiento de almacenamiento de la manguera del compresor Consulte la sección Características para conocer las ubicaciones de la manguera del compresor Los botón con desc power del compresor y botones del control de presión del compresor están situados en el panel de control en el fre...

Страница 14: ...a los dos primeros puertos USB no excede 3 1A y o el consumo total de todos los dispositivos USB conectados a la parte inferior dos puertos USB no exceda 3 1A Si un dispositivo USB individuo está dentro de las especificaciones y se produce el fallo tener el dispositivo USB comprobado para funcionamiento defectuoso y no seguir utilizándolo con estos puertos USB Usando los puertos USB 1 Pulse el bot...

Страница 15: ...el USB Compruebe que la unidad tiene una carga completa Recargue la unidad en caso de necesidad La luz de área LED no enciende Cerciórese de que el botón de encendido de la luz de área LED esté en la posición de trabajo Compruebe que la unidad tiene una carga completa Recargue la unidad en caso de necesidad ACCESORIOS Accesorios recomendados para uso con esta unidad puede ser disponibles a través ...

Страница 16: ...30 31 PP1DCS_ManualENSP_072116 indd 30 31 7 27 2016 10 20 09 AM ...

Отзывы: