154099 / 8591601300
S-BA-8591-04-en-04/09/2009
Maintenance
25
Ex Plug Connector miniClix
8591/1, 8591/4
11394E00
X
Rotate the connector plug/coupler by about 30° to the right until you reach the
second stop (3).
X
Fully insert the plug into the socket (4).
X
Fasten the union nut (5).
Z
The mechanical connection as well as the IP protection are now established.
X
Proceed in reverse order to disconnect the plug connector.
9
Maintenance
WARNING
Danger from energised parts!
Z
Explosion protection is not guaranteed any longer.
X
Ensure that the plug/device plug is voltage free when the plug connection
is disconnected.
X
Energised couplers/flange sockets must be closed off by means of
protective caps immediately after disconnection.
WARNING
Short-circuit in the circuit
Z
After multiple short circuits, the flameproof encapsulation is no longer
guaranteed.
X
After a short circuit, check the functionality of the plug connector.
X
Replace the entire plug connector if needed.
WARNING
Work on gap limiting surfaces!
X
Gap limiting surfaces are neither to be reworked nor lacquered after purchase of the
device.