Installation
20
154099 / 8591601300
S-BA-8591-04-en-04/09/2009
Ex Plug Connector miniClix
8591/1, 8591/4
X
Push the sleeve (5) over the screen wire shielding.
11384E00
X
Screw the inner gland nut (4) onto the plug sleeve.
Z
The sleeve clamps the screen wire shielding onto the clamping cone.
Z
The seal clamps the inner sheath of the connecting cable.
X
Place the thrust ring (3) and seal (2) against the gland nut (1).
X
Make sure that the seal sits correctly.
X
Screw the gland nut (1) onto the inner gland nut (4) using the corresponding tightening
torque (see technical data).
11385E00
7.8 Plug/coupler (Ex-e) - plastic/metal 4-pole (3 + PE) with cage clamp terminal
11386E00
X
Strip the insulation as depicted in the drawing.
X
Open the cage clamp terminal (2) using an appropriate tool (1)
(e.g. screwdriver 2.5 x 75).
X
Insert the connecting cable (3).
X
Pull the tool out.
Z
In so doing, the cage clamp spring is pressed against the connecting cable.
Z
Electrical contact between connecting cable and plug pin is established.
X
Proceed in reverse order to undo the connection.