272350 / 610260300020
2019-07-25·BA00·III·en·00
Annex A
31
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Compact Luminaire with LED
Series C-Lux 6102/1, Series C-Lux 6109/1
Power factor
230 V:
)
0.90
100 V:
)
0.99
Degree of protection IP66 / IP67 (IEC 60598)
IP64 if a breather is used
Protection class
I (with internal PE connection)
Luminous characteristics
Colour rendering
Ra
)
80
Colour temperature
5,000 K
Luminous flux
Values apply to T
a
= +25 °C.
Luminance
Light panel green: L
m
= 145 cd/m
2
Light panel white: L
m
= 1,400 cd/m
2
Luminous flux
decrease
No luminous flux decline
• Within the permissible ambient temperature range
• During DC operation (only Series 6102/1)
Luminous flux decline during battery operation (only Series 6109/1)
• By 50% for a rated operating time of 1.5 h
• By 75% for a rated operating time of 3.0 h
Ambient conditions
Operating
temperature
range
1) Rated operating time during emergency light operation
is guaranteed in an ambient temperature range from -5 to +60 °C.
Outside of this temperature range, the rated operating time can be shortened.
2) Battery service life
is guaranteed in an ambient temperature range of -30 to +60 °C corresponding
to IEC/EN 60598-2-22.
Storage
6102/1:
Storage temperature -40 to +70 °C
6109/1:
depending on the storage duration:
up to 1 week: -20 to +55 °C
up to 1 month: -20 to +45 °C
over 1 month: -20 to +30 °C
Technical Data
Optics
with diffuser
without diffuser with deflection
optics
Luminous flux [lm]
600
775
490
Luminaire efficacy
[lm/W]
62
80
51
Variant
6102/1
St DALI
6102/1
ADR
6109/1
St DALI
no through wiring
-40 to +60 °C
-30 to +60 °C -30 to +60 °C
1) 2)
I
N
through wiring
max. 3 x 10 A
-40 to +60 °C
-30 to +60 °C -30 to +60 °C
1) 2)
I
N
through wiring
max. 3 x 16 A
-40 to +50 °C
-30 to +50 °C -30 to +50 °C
1) 2)