background image

Operation, Installation and Maintenance Manual for 6414/11-Series 

 

 

ID-No.:  

                   240912 / 6414603300

 

Publication Code:          2015-04-30:BA00.lll.en.00                                                                                                                                                                                Page - 15 - of 17 

 

 

9.

 

Operations                                                                                                      

9.1 

Trouble shooting 

 

Cause 

Measure 

The lamp was incorrectly inserted.

 

Insert the lamp correctly.

 

The lamp is defective.

 

Replace the lamp.

 

The ballast is defective.

 

Replace the ballast.

 

The power switch is defective.

 

Replace the switch.

 

The lamp reached its end of service life.

 

Replace the lamp.

 

 

If the error cannot be eliminated using the mentioned procedures: 

 

Contact the local representative of R. STAHL Schaltgeräte GmbH.

 

For fast processing, have the following information ready: 

 

Type and serial number 

 

Purchase information 

 

Error description 

 

Intended use (in particular input / output wiring) 

10.

 

Maintenance and repair                                                                       

 

WARNING 

Unauthorized work being performed on the device!  

Risk of injuries and material damage! 

 

Work performed on the device must only be carried out by appropriately authorized and trained 
personnel. 

 

Risk of electric shock or malfunctioning of the device due to unauthorized work! 

Non-compliance can result in severe injuries and material damage. 

 

Work performed on the device must only be carried out by appropriately authorized and qualified 
electricians. 

 

 

10.1 

Maintenance 

 

Observe the relevant national regulations in the country of use.

 

 

Consult the relevant national regulations to determine the type and extent of inspections. 

 

Adapt inspection intervals to the operating conditions. 

 

 

 

Содержание 6414/11 Series

Страница 1: ...Manual for 6414 11 Series ID No 240912 6414603300 Publication Code 2015 04 30 BA00 lll en 00 Page 1 of 17 Operating instructions For Additional languages www stahl ex com Linear Luminaire Sheet Steel...

Страница 2: ...3 2 Safe Use 4 3 3 Intended Use 5 3 4 Modification and Alterations 5 4 Function and Device Design 5 4 1 Function 6 4 2 Device design 6 5 Technical Data 7 6 Transport and Storage 8 7 Mounting Installa...

Страница 3: ...ons ID No 240912 6414603300 Publication Code 2015 04 30 BA00 lll en 00 The original instructions are the English edition They are legally binding in all legal affairs 1 3 Conformity to Standards See c...

Страница 4: ...s Non compliance with the instruction can result in minor or light injuries to persons NOTICE Avoiding material damage Non compliance with the instruction can result in material damage to the device a...

Страница 5: ...s prohibited Installation maintenance overhaul and repair may only be carried out by appropriately authorized and trained personnel Non compliance to this could be fatal or could result in damage to t...

Страница 6: ...lighting areas work spaces and objects switching off the equipment by means of a central lock Optional version when the luminaire is opened For lighting areas work spaces and objects Pharma Chemical...

Страница 7: ...50 60 Hz Lamp operation DC 2 lamp Lamp standard IEC 60081 Lamp power 18 36 58 W Nominal current 2x 18 W 150 mA 4x 18 W 300 mA 2x 36 W 300 mA 4x 36 W 600 mA 2x 58 W 480 mA 4x 58 W 960 mA Lamp Wattage 1...

Страница 8: ...Optional With Disconnect Switch Light technical data Lamps Two pin fluorescent lamps 26 mm diameter for holder G13 2 x 18 W 4 x 18 W 2 x 36 W 4 x 36 W 2 x 58 W 4 x 58 W Installation notes Looping thr...

Страница 9: ...ublication Code 2015 04 30 BA00 lll en 00 Page 9 of 17 7 1 Dimensions fastening dimensions Dimensional Drawings All Dimensions in mm inch Subject to Alterations Model 2x18W 4x18W 2x36W 4x36W 2x58W 4x5...

Страница 10: ...on protection is impaired Do not install within arm s reach Ensure that no electrostatic charging may occur For example due to accidental friction with particle streams by cleaning with a dry cloth Th...

Страница 11: ...ire by using a socket wrench from R STAHL Schaltger te GmbH 1 Remove the closing cap of the central lock 2 To open the fixture press inward and Turn the central lock using a socket key M5 hex socket h...

Страница 12: ...reflector plate by two 2 No s quarter turn screws 2 Swivel down the reflector plate as shown in the diagram below 3 When closing flip up the reflector plate snap it into place and fix it with by two...

Страница 13: ...mm 10 11 mm Through wiring NOTE Through wiring with 2 5 mm 2 cross section for max 12 A 7 3 3 Cable Entries The standard luminaire is delivered with 3 lead in holes 1 cable gland and 2 stopping plugs...

Страница 14: ...device before commissioning Explosion protection is impaired Comply with the National regulations Check the device for proper installation and function before commissioning Before commissioning ensur...

Страница 15: ...on ready Type and serial number Purchase information Error description Intended use in particular input output wiring 10 Maintenance and repair WARNING Unauthorized work being performed on the device...

Страница 16: ...ely change enclosure components with foamed seal if the conductors are clamped properly clamp loose conductors tightly 10 1 1 Replacement of lamps Only use fluorescent lamps with pins made of brass In...

Страница 17: ...als when sending it for recycling Ensure environmentally friendly disposal of all components according to the statutory regulations 12 Accessories and Spare Parts NOTE Use only original accessories an...

Отзывы: