Binary output

Series 9175

15

Appendix B

15.1 Device Design

15.2 Dimensions/Fastening Dimensions

#

Device element

Description

07450E00

1

Black terminals

Connection terminals for the safe area

2

Green "PWR" LED

Auxiliary power indication

3

Red "LF1" LED

Indication of line fault detection for 

channel 1

4

Red "LF2" LED

Indication of line fault detection for 

channel 2

5

DIP switch "LF1"

Activation of line fault detection for 

channel 1

7

DIP switch "LF2"

Activation of line fault detection for 

channel 2

9

Blue terminals

Connection terminals for the 

hazardous area (intrinsically safe Ex i)

16

"OUT1" LED

Output 1 status indication

17

"OUT2" LED

Output 2 status indication

1

9

2

16
5

7

4

3

17

9175

Dimensional drawings (all dimensions in mm [inch]) – Subject to change

09685E00

Dimension X

Screw 

terminals

108 [4.25]

Spring clamp 

terminals

128 [5.04]

X

122  4 80

[,

]

114,5  4 51

[,

]

99  3 90

[ ,

]

17,6 [0,69]

Содержание 160404

Страница 1: ...Bin rausgabe Reihe 9175 Betriebsanleitung Additional languages r stahl com DE GB FR IT ES RU NL DK SE FI PT GR PL CZ SK HU SL RO BG LV LT EE CH KR CN F r k nftige Verwendung aufbewahren...

Страница 2: ...ifikation des Personals 5 3 3 Restrisiken 6 4 Transport und Lagerung 8 5 Produktauswahl und Projektierung 8 6 Montage und Installation 8 6 1 Montage Demontage 8 6 2 Installation 10 7 Parametrierung un...

Страница 3: ...aktualisieren Die Originalbetriebsanleitung ist die deutsche Ausgabe Diese ist rechtsverbindlich in allen juristischen Angelegenheiten 1 3 Weitere Dokumente Installationsanleitung Schaltschrank Datenb...

Страница 4: ...en zu schweren Verletzungen f hren kann VORSICHT Gefahrensituation die bei Nichtbeachtung der Sicherheitsma nahmen zu leichten Verletzungen f hren kann HINWEIS Gefahrensituation die bei Nichtbeachtung...

Страница 5: ...ng geh rt die Beachtung dieser Betriebsanleitung und der mitgeltenden Dokumente z B des Datenblatts Alle anderen Anwendungen sind nur nach Freigabe der Firma R STAHL bestimmungsgem 3 2 Qualifikation d...

Страница 6: ...erpackung bef rdern die das Ger t vor u eren Einfl ssen sicher sch tzt Bei der Auswahl der Transportverpackung Umgebungsbedingungen siehe Kapitel Technische Daten ber cksichtigen Ger t nicht belasten...

Страница 7: ...en die den Verschmutzungsgrad 2 nicht berschreiten Stromkreise der Z ndschutzart Ex i die mit Stromkreisen anderer Z ndschutzarten betrieben wurden d rfen danach nicht mehr als Stromkreise der Z ndsch...

Страница 8: ...enau durchlesen und exakt befolgen 6 1 1 Gebrauchslage Die Gebrauchslage ist beliebig 6 1 2 Montage Demontage pac Bus Der pac Bus ist ein Zubeh r das die Verdrahtung der Hilfsenergie und das Auslesen...

Страница 9: ...s auf die Au enkante der Hutschiene setzen Ger t auf Hutschiene aufrasten Beim Aufschwenken des Ger ts auf die Hutschiene darauf achten dass es nicht verkantet Montage auf pac Bus 15554E00 Der pac Bus...

Страница 10: ...e ansetzen Klemme herausdr cken 6 2 Installation 6 2 1 Elektrische Anschl sse Prinzipschaltbild Siehe Ger teaufdruck 6 2 2 Anschluss der Speisung Haupt bzw Hilfsenergie nach folgendem Schema anschlie...

Страница 11: ...arametrierungen DIP Schalterstellungen f r Leitungsfehlererkennung LF Standardeinstellung bei Auslieferung Die nderung der DIP Schalter Einstellungen ist im Betrieb auch in der Zone 2 und bei angeschl...

Страница 12: ...schnellen Bearbeitung folgende Angaben bereithalten Typ und Seriennummer des Ger ts Kaufdaten Fehlerbeschreibung Einsatzzweck insbesondere Eingangs Ausgangsbeschaltung LED Farbe LED EIN LED AUS LED PW...

Страница 13: ...n tigt keine regelm ige Wartung Ger t gem den geltenden nationalen Bestimmungen und den Sicherheitshinweisen dieser Betriebsanleitung Kapitel Sicherheit warten 9 3 Reparatur Reparaturen am Ger t nur d...

Страница 14: ...em Recycling zuf hren Umweltgerechte Entsorgung aller Bauteile gem den gesetzlichen Bestimmungen sicherstellen 13 Zubeh r und Ersatzteile 14 Anhang A 14 1 Technische Daten Kennzeichnung HINWEIS Fehlfu...

Страница 15: ...x anschlie bare Kapazit t Co IIC 1 79 F IIB 12 1 F Max anschlie bare Induktivit t Lo IIC 6 3 mH IIB 25 mH Innere Kapazit t Ci 1 1 nF Innere Induktivit t Li vernachl ssigbar Sicherheitstechnische Maxim...

Страница 16: ...ehler LED rot LF je Kanal Meldung Leitungsfehler und Hilfsenergieausfall Kontakt 30 V 100 mA im Fehlerfall gegen Masse geschlossen pac Bus potentialfreier Kontakt 30 V 100 mA Technische Daten Sicherhe...

Страница 17: ...9175 20 14 11 2 Kan le Fehlererkennung Ex i Ausgang Drahtbruch je Ausgang 10 k 10 k zwei Ausg nge parallel 5 k Kurzschluss je Ausgang bei 23 C 40 80 6 10 K 40 80 6 10 K zwei Ausg nge parallel bei 23 C...

Страница 18: ...H IIB 9 mH Innere Kapazit t Ci 1 1 nF Innere Induktivit t Li vernachl ssigbar Sicherheitstechnische Maximalspannung 253 V AC H chstwerte bei zwei parallel geschalteten Ausg ngen siehe Datenblatt Elekt...

Страница 19: ...hlerfall gegen Masse geschlossen pac Bus potentialfreier Kontakt 30 V 100 mA Technische Daten Elektrische Daten Hilfsenergie Nennspannung UN 24 V DC Spannungsbereich 18 31 2 V Restwelligkeit innerhalb...

Страница 20: ...stemperatur Einzelger t 20 65 C Gruppenmontage 20 65 C Einbaubedingungen beeinflussen die Umgebungstemperatur Installationsanleitung Schaltschrank beachten Lagertemperatur 40 80 C Relative Feuchte kei...

Страница 21: ...e Leitungsfehlererkennung f r Kanal 1 4 LED LF2 rot Anzeige Leitungsfehlererkennung f r Kanal 2 5 DIP Schalter LF1 Aktivierung der Leitungsfehlererkennung f r Kanal 1 7 DIP Schalter LF2 Aktivierung de...

Страница 22: ......

Страница 23: ...Binary output Series 9175 Operating instructions Additional languages r stahl com DE EN FR IT ES RU NL DK SE FI PT GR PL CZ SK HU SL RO BG LV LT EE CH KR CN Save for future use...

Страница 24: ...tion 5 3 3 Residual Risks 6 4 Transport and Storage 8 5 Product Selection and Project Engineering 8 6 Mounting and Installation 8 6 1 Mounting Dismounting 8 6 2 Installation 10 7 Parameterisation and...

Страница 25: ...ons every time R STAHL issues an amendment The original instructions are the German edition They are legally binding in all legal affairs 1 3 Further Documents Cabinet installation guide Data sheet FM...

Страница 26: ...evere injuries if the safety measures are not complied with CAUTION Dangerous situation which can result in minor injuries if the safety measures are not complied with NOTICE Dangerous situation which...

Страница 27: ...ntended use includes complying with these operating instructions and the other applicable documents e g the data sheet All other uses are only intended after being approved by R STAHL 3 2 Personnel Qu...

Страница 28: ...influences Observe the ambient conditions when selecting the transport packaging see the Technical data chapter Do not place any loads on the device Check the packaging and the device for damage Repor...

Страница 29: ...vironments not exceeding degree of pollution 2 Electrical circuits with the Ex i type of protection may no longer be operated as electrical circuits with this type of protection after being operated w...

Страница 30: ...sembly instructions carefully and follow them precisely 6 1 1 Operating Position The operating position is optional 6 1 2 Mounting Dismounting pac Bus The pac Bus is an accessory which makes it easier...

Страница 31: ...e on the outside edge of the DIN rail Engage the device on the DIN rail When swivelling the device onto the DIN rail make sure that it is not set at an angle Mounting on pac Bus 15554E00 The pac Bus i...

Страница 32: ...ewdriver behind the terminal Push out the terminal 6 2 Installation 6 2 1 Electrical Connections Schematic Diagram See device labelling 6 2 2 Connection of Supply Connect the main and auxiliary power...

Страница 33: ...ry 7 2 Parameterisation DIP switch positions for line fault detection LF Standard setting upon delivery Changing the DIP switch settings is also permitted during operation in Zone 2 and with connected...

Страница 34: ...altger te GmbH For rapid processing have the following information ready Type and serial number of the device Purchase information Error description Intended purpose especially input output circuit LE...

Страница 35: ...ed Ensure it is being used as intended 9 2 Overhaul The device does not require regular maintenance Perform overhaul of the device according to the applicable national regulations and the safety notes...

Страница 36: ...friendly disposal of all components according to statutory regulations 13 Accessories and Spare Parts 14 Appendix A 14 1 Technical Data Label NOTICE Malfunction or damage to the device due to the use...

Страница 37: ...connectable capacitance Co IIC 1 79 F IIB 12 1 F Max connectable inductance Lo IIC 6 3 mH IIB 25 mH Internal capacitance Ci 1 1 nF Internal inductance Li negligible Safety related maximum voltage 253...

Страница 38: ...ch activated deactivated Line fault indication Red LF LED per channel Message line fault and auxiliary power failure contact 30 V 100 mA closed against earth in case of error pac Bus potential free co...

Страница 39: ...9175 20 14 11 2 channels Ex i output error detection Wire breakage per output 10 k 10 k two parallel outputs 5 k Short circuit per output at 23 C 40 to 80 6 10 K 40 to 80 6 10 K two parallel outputs a...

Страница 40: ...ce Ci 1 1 nF Internal inductance Li negligible Safety related maximum voltage 253 V AC Maximum values for two outputs connected in parallel see data sheet Electrical data Ex i output Output characteri...

Страница 41: ...e of error pac Bus potential free contact 30 V 100 mA Technical data Electrical data Auxiliary power Nominal voltage UN 24 V DC Voltage range 18 to 31 2 V Residual ripple within the voltage range 3 6...

Страница 42: ...Group assembly 20 to 65 C Installation conditions influence the ambient temperature Observe the Cabinet installation guide Storage temperature 40 to 80 C Relative humidity no condensation 95 Use at h...

Страница 43: ...fault detection for channel 1 4 Red LF2 LED Indication of line fault detection for channel 2 5 DIP switch LF1 Activation of line fault detection for channel 1 7 DIP switch LF2 Activation of line faul...

Страница 44: ......

Отзывы: