![Srne HF2430S80-H Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/srne/hf2430s80-h/hf2430s80-h_user-manual_1354162029.webp)
Solar charge inverter V1.0 29
4.3 Battery type parameters
For Lead-acid Battery :
Battery type
Parameters
Sealed lead acid
battery (SLD)
Colloidal lead
acid battery
(GEL)
Vented lead
acid battery
(FLD)
User-defined
(User)
Overvoltage disconnection voltage
30.0V
30.0V
31.0V
18~30V
Battery fully charged recovery
point(setup item 37)
26V
(Adjustable)
26V
(Adjustable)
26V
(Adjustable)
26V
(Adjustable)
Equalizing charge voltage
29.2V
-
29.6V
18~30V
Boost charge voltage
28.8V
28.4V
29.2V
18~30V
(Adjustable)
Floating charge voltage
27.6V
27.6V
27.6V
18~30V
(Adjustable)
Undervoltage alarm voltage(01 fault)
22V
22V
22V
18~30V
(Adjustable)
Undervoltage alarm voltage
recovery
point(01 fault)
Undervoltage alarm 0.4V
Low voltage disconnection voltage(04
fault)
21.0V
21.0V
21.0V
18~30V
(Adjustable)
Low voltage disconnection voltage
recovery point (04 fault)(setup item
35)
26V
(Adjustable)
26V
(Adjustable)
26V
(Adjustable)
26V
(Adjustable)
Discharge limit voltage
20.0V
20.0V
20.0V
18~30V
(Adjustable)
Over-discharge delay time
5s
5s
5s
1~30s
(Adjustable)
Equalizing charge duration
120
minutes
-
120
minutes
0~600
minutes
(Adjustable)
Equalizing charge interval
30
days
-
30
days
0~250
days
(Adjustable)
Boost charge duration
120
minutes
120
minutes
120
minutes
10~600
minutes
(Adjustable)