Standard Control Board
3.0 OPERATION
3.1 Start-up
3.1.1 Controller Settings- Set or verify settings on controller
3.1.1.1 Standard Control Board
WARNING
Enclosure may have live electric parts.
De-energize dryer before opening enclosure.
3.1.1.1.1 Voltage Selection -
Set the voltage selection switch located at the lower edge of the power
board for the proper voltage.
3.1.1.1.2 Dip Switch Settings - (Refer to Table 3A)
NOTE: For ON DIP switch is up; OFF DIP switch is down
To select Test Mode - place switch 5 and 6 in ON position
Right Inlet Solenoid Energized LED
Left Purge/Repressurization Solenoid Energize LED
Right Purge/Repressurization Solenoid Energized LED
Left Inlet Solenoid Energized LED
DIP Switches for Economizer Setting,
Standard or HP selection,
Cycle/Mode selection
Alarm Hook-up
Power Hook-up
Voltage Selection Switch
Soleniod circuit fuse
1.25A 250V
Control circuit fuse
125m A 250V
Tower Pressure Switches Open @40 psig
Close @45 psig
RESET/STEP