IMPORTANT: 
READ PRIOR TO STARTING THIS EQUIPMENT

A. UNPACKING
  This shipment has been thoroughly checked, packed and inspected 

before leaving our plant.  It was received in good condition by the car-

rier and was so acknowledged.

1. Check for Visible Loss or Damage.  If this shipment shows evidence of 

loss or damage at time of delivery to you, insist that a notation of this 

loss or damage be made on the delivery receipt by the carrier’s agent.

2. Check for Concealed Loss or Damage.  When a shipment has been 

delivered to you in apparent good order, but concealed damage is 

found upon unpacking, notify the carrier immediately and insist on his 

agent inspecting the shipment.  Fifteen days from receipt of shipment 

is the maximum time limit for requesting such inspection.  Concealed 

damage claims are not our responsibility as our terms are F.O.B. point 

of shipment.

B. MOVING CAUTION: 
  Do not lift by piping. Use lifting lugs or fork lift.

GENERAL SAFETY 

INFORMATION

1. Pressurized devices: This equipment is a pressure 

containing device. Do not exceed maximum operating 

pressure as shown on equipment serial number tag.  

Make sure equipment is depressurized before working 

on or disassembling it for service.

2. Electrical: This equipment requires electricity to operate. 

Install equipment in compliance with national and local 

electrical codes.  Standard equipment is supplied with 

NEMA 4, 4x electrical enclosures and is not intended for 

installation in hazardous environments.  

  Disconnect power supply to equipment when performing 

any electrical service work.

3. Breathing  Air: Air treated by this equipment may not be 

suitable for breathing without further purification.  Refer 

to OSHA standard 1910.134 for the requirements for 

breathing quality air.

4. Noise: Do not operate dryer without mufflers installed.

5. High Velocity Air: Do not stand near mufflers during 

tower depressurization.

I. INSTALLATION

1.  Install on level surface.

2.  Ambient temperature range: 35 to 120°F (1.7 to 49°C)  

 

[ if low ambient package supplied: -10 to 120°F (-23 to 49°C) ]

3.  Install purge mufflers if shipped separately.

4.  Connect air from compressor to inlet.

•  Maximum compressed air temperature: 120°F (49°C)

•  Maximum compressed air pressure: Refer to serial number 

tag.

•  Minimum compressed air pressure: 100 psig (6.9 barg) 

5.  Connect outlet to air system.

6.  Refer to serial number tag for correct voltage. Make electrical 

connection to terminal strip in control panel. Connect line to 

position 5, neutral to position 6 and ground to position 7.

7.  Verify voltage selector switch (115V or 230V).  Position should 

match voltage on Serial Number Tag.

II.  START UP

1.

 

Set or verify controller settings. See section 3.1.1.

2.  SLOWLY pressurize unit.

3.  Energize dryer by turning on/off switch on. (“I” is on; “O” is off)

4.  Adjust purge air flow rate. Turn purge rate valve until Purge 

Pressure Gauge reads as shown in the following table. 

 

NOTE: One tower must be purging when setting purge pressure.

MINI INSTRUCTIONS

For complete instructions on installation, operation and maintenance, consult manual.

III.  OPERATIONAL CHECKPOINTS

1.  Check that dryer is energized (indicating lights are illumi-

nated) 

2.  MOISTURE INDICATOR - Indicator should be green (Allow 

4 hours after start up for indicator to turn green).

3.  TOWER PRESSURE GAUGES - 

•  Tower on line should read line pressure

•  Tower off line should read 2 psig (0.14 barg)or less while 

purging.  If pressure exceeds 2 psig (0.14 barg) replace 

purge muffler elements.

NOTE:  An extra set of elements is shipped with dryer. 

4.  PURGE PRESSURE GAUGE - Verify proper setting.

5.  CHECK FOR ALARM CONDITION.

IV. DEPRESSURIZATION

Isolate dryer.  Run timer until both tower pressure gauges read 

0 psig (0 kgf/cm

2

)(test mode may be used to speed up cycle).

Содержание RDH-HP Series

Страница 1: ...1550G RDH HP 5200G FOR M NO 3245430 R EVI S ION 04 2014 R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT I N STR UCTION MAN UAL MODELS RATED FLOW REFER...

Страница 2: ...red or replaced under warranty shall be warranted for the unexpired portion of the warranty applying to the original product The foregoing is the exclusive remedy of any buyer of the manufacturer s pr...

Страница 3: ...se Do not operate dryer without mufflers installed 5 High Velocity Air Do not stand near mufflers during tower depressurization I INSTALLATION 1 Install on level surface 2 Ambient temperature range 35...

Страница 4: ...arg are possible or reduce the moisture content of compressed air when used in critical process applications These dryers continuously dry compressed air by using two identical towers each containing...

Страница 5: ...sses through purge and repressurization valve 9B normally closed and purge muffler 10B to the atmosphere After regeneration purge and repressurization valve 9B normally open closes allowing tower 4B t...

Страница 6: ...r does not increase desiccant dryer capacity or reduce purge flow requirements However a cooling unit installed ahead of the desiccant dryer reduces the inlet air temperature and outlet air dew point...

Страница 7: ...ication Air Inlet Air Outlet Left Tower Pressure Gauge Right Tower Pressure Gauge Purge Pressure Gauge Electrical Entry Inlet Pressure Gauge Outlet Pressure Gauge Automatic Condensate Drain Purge Muff...

Страница 8: ...S 3 BOSS FITTING TOP VIEW ELECTRICAL ENCLOSURE SEE DETAIL SIDE VIEW SEE AC SIDE DETAIL RIGHT TOWER PRESSURE GAGE PURGE PRESSURE GAGE PURGE PRESSURE ADJUSTMENT VALVE DESICCANT FILL PORT FRONT VIEW LEFT...

Страница 9: ...PRESSURE GAUGE PURGE PRESSURE GAUGE RIGHT TOWER PRESSURE GAUGE ELECTRICAL ENCLOSURE NEMA CLASS 4 4X POWER SWITCH 3 PRONG MALE ELECTRICAL PLUG DETAIL A TOWER PRESSURE RELIEF VALVE PURGE MUFFLER PROCESS...

Страница 10: ...TLET SHUT OFF VALVE NPS 3 4 PLACES SEE SECTION B DESICCANT FILL PORT AIRLINE AFTERFILTER HF7 76 6F S MOUNTING HOLES 1 INCH DIA 6 PLACES PURGE MUFFLER 3 1 2 X 9 1 2 FORKLIFT OPENINGS 90mm X 241mm 2 PLA...

Страница 11: ...yer without one of the above measures Exhausting air will result in noise levels above OSHA permissible levels and exhausting gas could potentially cause harm to persons or property 2 8 Initial Desicc...

Страница 12: ...enoid Energized LED Left Purge Repressurization Solenoid Energize LED Right Purge Repressurization Solenoid Energized LED Left Inlet Solenoid Energized LED DIP Switches for Economizer Setting Standard...

Страница 13: ...various inlet temperatures NOTE During start up the indicator may be yellow however it should begin to change to green within four hours 3 2 1 3 Purge Flow Indicator Every four hours check the purge...

Страница 14: ...xcessive air is discharged through the muffler on the right check if valve 5b or 5c is sticking 3 3 Shut Down 3 3 1 Depressurize dryer 3 3 1 1 Open by pass valve if one is installed and close inlet an...

Страница 15: ...0 1 43 174 120 42 0 165 42 72 75 0 273 210 1 40 174 120 43 0 169 42 72 77 0 279 200 1 37 174 120 44 0 172 42 72 79 0 286 190 1 34 174 120 46 0 177 42 72 81 0 293 180 1 30 174 120 47 0 181 42 72 84 0 3...

Страница 16: ...r dryer operation Never use hygroscopic salts of the type com monly used in deliquescent type dryers 4 1 1 Frequency of desiccant replacement Desiccant should be replaced whenever the required dew poi...

Страница 17: ...4 Test Mode WARNING Enclosure contains electricity Use caution when working inside box 4 5 1 Test Mode Standard Control Panel 4 5 1 1 Wait until point in cycle when right tower is drying and left towe...

Страница 18: ...e correct Economizer Switch and Cycle Set tings Refer to Section 3 2 3 to verify proper time sequence 5 4 Tower fails to pressurize to line pressure Purge repressurization valve won t close Excessive...

Страница 19: ...011100 4011100 4011100 1 Purge Muffler Replacement Core 3097672 1 Purge Muffler Replacement Core 72378 72378 8 Aftercooler Air Filter Silencer Replacement Core 3211091 3211091 3211091 1 Aftercooler Te...

Страница 20: ...5200G SPX 1000 Philadelphia Street Canonsburg PA 15317 1700 U S A P 724 745 1555 F 724 745 6040 E hankison rental spx com www rentaldryers com Improvements and research are continuous at SPX Specifica...

Отзывы: