6
3.4 SYSTEM USAGE
•
Spray controller provide on/off timing and flow control of the nozzles
•
Will feed directly: the liquid delivery line, distribution manifold, and nozzle (s).
•
Conditioning fluid pump should be primed and ran using clean water.
•
Agitator component should be used with filtered, regulated, and lubricated air.
•
Process fluid can be drained using 3
-
way ball valve on the fluid outlet.
•
Zone control panel for specific application targeting by turning on and off individual groups or nozzles.
3.5 LIQUID DELIVERY TANK
•
10 gallon, 304 stainless steel ASME pressure tank
•
Air inlet with manual air inlet pressure regulator, gauge, manual 2
-
way ball valve for quick safety relief of tank
pressure.
•
Continuous liquid level sensor with auto
-
refill addition.
•
Liquid outlet unit with manual 3
-
way ball valve for tank draining, and 2
-
way ball valve for direct fluid line shut off.
•
Air motor driven liquid agitator unit that is equipped with a stainless
-
steel shaft propeller.
•
The regulator
-
filter
-
lubricator must be mounted by the customer and provided its own separate line of air for the
air motor on the agitator.
3.6 ZONING CONTROL SYSTEM OPTIONS
Optional zone control provides the means to individually trigger spray nozzles or groups of spray nozzles. The system
includes the following equipment to enable zone control:
NOTE:
Zone control provides the ability to trigger the spray nozzles, or groups of spray nozzles, independently,
however, all spray nozzles will operate at the same duty cycle.
Figure 2: Manual Zone Control (Optional)
Figure 3: Digital Zone Control (Optional)
Filter/Regulator/
Lubricator