17
SECTION 8
TROUBLESHOOTING
1) System won
’
t power on:
a.
Be sure disconnect is on
b. Measure power input at the disconnect
c. Check fuses
2) System does not spray:
a.
Check air supply pressure on tank
b.
Check air pressure in tank
c.
Check ball valves at the bottom of the tank
d.
Power to the Spray Control Panel
e.
Check wiring between the Spray Control Panel and the PulsaJet gun(s)
f.
Verify Trigger signal
g.
Fluid may have solidified in supply lines, reconfigure heating supply, or increase temperature.
h.
Check nozzle for clogging.
3) Conditioning Fluid pressure low (less than 10psi):
a. Air in the system, purge
b. Check for leaks in the conditioning line circuit, tighten or replace fittings
4) System not heating:
a. Check for power
b. Check heater selector switch
c. Check the heating circuit level switch
•
Yellow lights near M12 connector, system should run
•
No lights present, insufficient water in the heating jacket loop or damaged sensor.
d. Heater faulty, or maximum temperature exceeded, Press the "EZ" button on the heat controller to reset.
SECTION 9
SPARE PARTS
Part Number
Description
AA10000
-
72440T
-
EPM8
Heated PulsaJet Spray Nozzle
-
Threaded Connection.
LS00LMT100
Level Sensor, Point Switch.
PL00416TV
Air Vent
FT003133
-
JT_AC20
20 ft Jacketed Hose
PR00301DFW254D
Pressure Gauge, 0
-
60 psi.
TE00TM4341
RTD Temperature Sensor
HT00BHN717N5C
Heater, 6KW, 480VAC, 3
-
Alloy 800 elements, 304SS Nut
(2”
NPT),
17.75" Long.
VA0046495K23_AC01
Valve, Manual Ball Valve, 2
-
way, Threaded, Jacketed, 316SS.
VAXXEASSBBAFAF0_AC01
Valve, Manual Ball Valve, 3
-
way, Threaded, Jacketed, 316SS
VA007768K16
Check Valve, 1/4" NPT male x 1/4" NPT male, 1 PSI cracking pressure
VC00110
-
BC
1/4" Pressure Regulator, 1/4 NPT (female) End Plates, 0
-
100 PSI
VC003823T321
Regulator
-
Air/Water
-
For filling Heating Circuit
160TS16MV0018W5_SU01
Filter/regulator/Lubricator (FRL) Unit for oiled air supply to agitator